User's Manual

36
mn<cr><lf>
<cr><lf>OK<cr><lf>
22)
AT+BTSD?<cr>
<cr><lf>bdaddr of
secured device
1<cr><lf>
<cr><lf>bdaddr of
secured device
1<cr><lf>
<cr><lf>OK<cr><lf>
Query the bd-addresses of secured
devices
23)
AT+BTCSD<cr>
<cr><lf>OK<cr><lf>
Clear the list of secured devices
24)
AT+BTFP,n<cr>
<cr><lf>OK<cr><lf>
Force paring when connecting as
master
25)
AT+UARTCONFIG,baudrate,parity,st
opbit,handshaking<cr>
<cr><lf>OK<cr><lf>
Sets the configuration of UART
interface. Possible values are;
baud rate
=1200,4800,9600,19200,38400,5760
0 or 115200.
parity = (No parity), (Even parity) or
(Odd parity).
stop = 1 or 2.
Handshaking = 1 or 0
(If ‘1’, hardware handshaking will be
used. If ‘0’, handshaking function of
Parani10 will be turned off)
26)
AT+SETESC,nn<cr>
<cr><lf>OK<cr><lf>
Sets the escape sequence character.
nn should be ASCII code (Decimal),
and printable character. Default
escape character is +++
27)
AT+PINQ?<cr>
<cr><lf>OK<cr><lf>
For Periodic Inquiry. Parani10 will try
to inquire nearby Bluetooth devices
periodically and deliver the inquired
result to Host. To lease periodic
inquiry function, AT+BTCANCEL.
28)
AT&V Shows S-register values