C.5. S6: Enable Low Power Mode (default 0)
S10=0, deactivate Low Power Mode.
S10=1, activate Low Power Mode.
This value decides whether SD works in Low Power Mode or not. When this value is 0, SD works only in
active power mode. When SD works in Low Power mode, delay in transferring data may occur.
C.6. S10: Enable SD Response (default 1)
S10=0, Parani-ESD does not send SD responses to host system.
S10=1, Parani-ESD send SD responses to host system.
This value decides whether SD sends response messages such as OK, ERROR, CONNECT, DISCONNECT
or not. When this value is 0, SD sends no response messages. If the response messages cause troubles
in host programs or devices that is connected to SD, change this value to 0.
C.7. S11: Enable Escape (default 1)
S11=0, Parani-ESD does not allow escape sequence character. The operation status of Connect cannot be
changed to Standby. As Parani-ESD skips the process detecting escape sequence character, the more
efficient data transmission is expected.
S11=1, Parani-ESD allow escape sequence character. Whenever it is needed, the Connect status can be
changed to Standby.
C.8. S12: Clear Data Buffer When Disconnected (default 0)
S12=0, Parani-ESD does not clear the data buffer received from host system when disconnected.
S12=1, Parani-ESD clears the data buffer when disconnected.
C.9. S14: Enable DTR Transfer (default 1)
S14=0, DTR/DSR signal is transferred to loop-back.
S14=1, DTR signal is transferred to DSR of remote device.
C.10. S15: Enable Disconnect by DTR (default 0)
S15=0, DTR signal cannot release the connection.
S15=1, The Bluetooth connection can be released when DTR signal is off.
This value decides whether Bluetooth connection is released when DTR signal drops or not. If this value
is 1, you can use DTR signal in order to disconnect Bluetooth connection.
C.11. S22: Fast Connect (default 0)
S22=0, none
S22=1, page scan
S22=2, inquiry scan
S22=3, page/inquiry scan