User's Manual

Pro m i SD205-O A Use r Ma nua l – 2. C o nfig ura tio ns 9
A te rmina l Tp ro g ra m is a n a p p lic a tio n tha t will e na b le a PC to Tc o m munic a te d ire c tly with a mo d e m. If yo u a re using
Wind o ws 98SE o r hig he r ve rsio n o f Wind o ws, Hyp e rTe rm ina l p ro g ra m a s it is inc lud e d a s p a rt o f the o p e ra ting syste m.
Pro m i SD205-O A p ro vid e s so me e xte nd e d AT c o mma nd s fo r its c o nfig ura tio ns o n te rmina l p ro g ra m.
This ma nua l will e xp la in the m e tho d using Hyp e rTe rmina l. If yo u ne e d to insta ll Hyp e rTe rm ina l, c lic k sta rt>se tting >c o ntro l
p a ne l>a d d / re mo ve p ro g ra ms. Fo r mo re p re c ise info rma tio n, p le a se re fe r to He lp o f Mic ro so ft Wind o ws.
Atta c h Pro mi SD205-O A to se ria l p o rt o f ho st c o mp ute r a nd p o w e r o n. Sta nd b y LED is lit in g re e n.
La unc h Hyp e rTe rmina l. It c a n b e fo und in sta rt >p ro g ra ms >a c c e sso rie s >c o mm unic a tio n >Hyp e rTe rmina l. Se le c t the
Se ria l p o rt tha t Pro mi SD205-O A will b e c o nne c te d to .
Inp ut the sa m e se tting s into Se ria l p o rt c o nfig ura tio n wind o w a s Pro mi SD205-O A se tting s.
The se tting s ne e d to b e se t c o rre c tly, o the rw ise , e rro r me ssa g e ma y b e sho w n up o n the sc re e n o r c a use
ma lfunc tio ning o f Pro mi SD205-O A.
C ho o se the se tting s in File ->Pro p e rtie s->Se tting s->ASC II se tup tha t le t yo u turn e c ho o n in Hyp e rTe rm ina l; this will sho w
the re spo nse Pro mi SD205-O A se nd s o n the sc re e n.
Yo u no w g e t the Hyp e rTe rmina l w ind o w w he re yo u a re a b le to c o ntro l Pro mi SD205-O A with AT c o m ma nd s. Fo r
e xpa nd e d AT c o mma nd s tha t Pro mi SD205-O A p ro vid e s, p le a se re fe r to Ap p e nd ix A. AT c o mma nd s.
Exa m p le o f AT c o mma nd s:
Dip Switc h
With the c o m b ina tio n o f 4 slo t dip switc he s, b a ud ra te a nd ha rd wa re flo w c o ntro l c a n b e se t simp ly witho ut ho st
c o m p ute r.
Up p e r 3 d ip switc he s a re use d fo r se tting b a ud ra te , a nd b o tto m d ip switc h is use d fo r se tting ha rd wa re flo w c o ntro l
o p tio n. If the b a ud ra te ne e d s to b e se t o ut o f the ra ng e g ive n b e lo w, Pro miWIN o r te rmina l p ro g ra m sho uld b e use d
fo r e xte nd e d AT c o mma nd s. At this tim e c o mb ina tio n o f d ip switc he s must b e c o mp lie d with AT c md . The n b a ud ra te
will g o b a c k to 9600 a s d e fa ult.
AT+BTINFO?
000195000509,PSDv3b-000509,MODE0,STANDBY,0,0,HWFC
OK
AT+BTINQ?
00019520007E,PSDv2a-20007E,001F00
0004B300E205,AP2002:1 #0,020300
OK
ATD00019520007E
OK
CONNECT 0001952007E
Pairing Button
Dip Switch
Reset Button