8.1.3 S13
Description Get/Set the command responses mode.
Execute ATS13?<CR> ATS13=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default 1
Range 0 - 1
8.1.4 S14
Description
Get/Set the LED mode. It causes the LED operation if the device is ZE20S set
GPIO15, 16 to specific functionality.
0: LEDs are always OFF regardless of configuration or status.
1: LEDs are OFF when the node is under sleep status.
2: LEDs always operate by the case.
Execute ATS14?<CR> ATS14=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default 1
Range 0 - 2
8.2 Network Settings
8.2.1 S22
Description
Get/Set the timeout to permit joining. It determines the time in seconds that the device
will allow other devices to join to it when it starts network but an end-device cannot
perform it. If set to 255, the device will always permit joining.
Execute ATS22?<CR> ATS22=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default 255
Range 0 - 255
8.2.2 S23
Description
Get/Set the power boost mode of the module. If enabled, boost mode improves
sensitivity and increases output power, improving the link margin and range.
Execute ATS23?<CR> ATS23=<value><CR>
Response
<value><CR>
OK<CR>