User guide

ProBee-ZE20S-SExx User Guide Rev 1.8
74
0x000A
Time 0x0000
Time UTC_TIME
0x0001
Time Status INT8U
0x0800 Key establishment (Server Side)
0x0000
Key establishment suite ENUM16
0x0800 Key establishment (Client Side)
0x0000
Key establishment suite ENUM16
6.4.1.3 Commands
Table 6-4 ProBeeSESI Commands
Cluster
ID
Cluster name Comm
and ID
Command name Pay
load
AT Command
0x0000 Basic
(Server-side)
0x00 Reset to Factory Defaults - AT+FACTORYRESET
0x0003 Identify
(Server-side)
0x00 Identify 2 AT+IDENTIFY
0x01 Identify Query - AT+IDENQUERY
0x0700 Price
(Server-side)
0x00 Publish Price 51 AT+PRSETPUBLISH
0x01 Publish Block Period 17 -
0x0701 Demand
Response and
Load Control
(Server-side)
0x00 Load Control Event 23 AT+DLLOADCTRL
0x01 Cancel Load Control Event 12 AT+DLCANCELLOAD
0x02 Cancel All Load Control Events 1 -
0x0703 Messaging
(Server-side)
0x00 Display Message V AT+MSDISPLAY
0x01 Cancel Message 2 AT+MSCANCEL
0x0800 Key
establishment
(Server-side)
0x00 Initiate Key Establishment
Request
23 AT+CBKESTART
0x01 Ephemeral Data Request 22
0x02 Confirm Key Data Request 16
0x03 Terminate Key Establishment 4 -
6.4.2 ProBeeSEID (In-Premises Display)
The In-Premises Display device will relay energy consumption data to the user by way of a graphical or
text display. The display may or may not be an interactive device. At a minimum at least one of the
following should be displayed: current energy usage, a history over selectable periods, pricing information,
or text messages. As an interactive device, it can be used for returning simple messages for interpretation
by the recipient (e.g. “Button A was pressed”). The display may also show critical pricing information to
advise the customer when peaks are due to occur so that they can take appropriate action.