User guide
ProBee-ZE20S-SExx User Guide Rev 1.8
77
autonomously send readings periodically. A Metering end device may also be capable of communicating
certain status indicators (e.g. battery low, tamper detected).
6.4.3.1 Cluster Support
Table 6-8 ProBeeSEME Cluster Support
Server Side Client Side
Basic
Time
Identify
Messaging
Metering
Key establishment
Key establishment
6.4.3.2 Attributes
Table 6-9 ProBeeSEME Attributes
Cluster
ID
Cluster name Attribute
ID
Attribute name Type
0x0000 Basic 0x0000
ZCL version INT8U
0x0001
Application version INT8U
0x0002
Stack version INT8U
0x0003
Hardware version INT8U
0x0007
Power source ENUM8
0x0011 Physical environment ENUM8
0x0012
Device enabled BOOLEAN
0x0013
Alarm mask BITMAP8
0x0014
Disable local config BITMAP8
0x0003 Identify 0x0000
Identify time INT16U
0x0702 Metering 0x0000
Current summation delivered INT48U
0x0001
Current summation received INT48U
0x0002
Current max demand
delivered
INT48U
0x0003
Current max demand received
INT48U
0x0004
Dft summation INT48U
0x0200
Status BITMAP8