User guide

ProBee-ZE20S-SExx User Guide Rev 1.8
83
Execute AT+EPID?<CR> AT+EPID=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 0000000000000000
Range 0000000000000000 – FFFFFFFFFFFFFFFF
7.4.4 AT+GROUPID or AT+GI
Description Get/Set the 16-bit Group ID. It is used for multicast data reception.
Execute AT+GROUPID?<CR> AT+GROUPID=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 0000
Range 0000 – FFFF
7.4.5 AT+POWER or AT+PW
Description Get/Set the TX power at which the RF module transmits conducted power.
Execute AT+POWER?<CR> AT+POWER=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 8
Range -43 – 8
7.4.6 AT+STACK or AT+ZS
Description
Get/Set the ZigBee stack profile value. This value must be set the same on all
devices that should join the same network. (0: Network specific, 1: ZigBee, 2:
ZigBee Pro). Do NOT change default value if you want to use for Smart Energy
node.
Execute AT+STACK?<CR> AT+STACK=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 2
Range 0 – 2
7.4.7 AT+NODENAME or AT+NN
Description
Get/Set the node name. It can be used to make a clear distinction role or
functionality of local node from others.
Execute AT+NODENAME?<CR> AT+NODENAME=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>