User guide

ProBee-ZE20S-SExx User Guide Rev 1.8
86
Response OK<CR>
7.6.2 AT+PARENTLA or AT+PL
Description Get the 64-bit IEEE address of the parent node.
Execute AT+PARENTLA?<CR>
Response
<IEEE address><CR>
OK<CR>
7.6.3 AT+PARENTSA or AT+PS
Description Get the 16-bit Node ID of the parent node.
Execute AT+PARENTSA?<CR>
Response
<node ID><CR>
OK<CR>
7.6.4 AT+CHILDTABLE or AT+CT
Description Get the child table composed of the end-devices.
Execute AT+CHILDTABLE?<CR>
Response
<node type>|<IEEE address>|<node ID>
List of the child nodes
OK<CR>
7.7 Data Transmission and Reception
7.7.1 AT+MAXPAYLOAD or AT+MP
Description
Get the maximum size of the payload that the Application Support sub-layer will
accept. The size depends on the security level in use.
Execute AT+MAXPAYLOAD?<CR>
Response
<value><CR>
OK<CR>
7.8 Security
7.8.1 AT+SECURITY or AT+SE
Description
Get/Set the security status. (0: turning security off, 1: on) Every node must be
under the same security level in the network. Do NOT change default value if you
want to use for Smart Energy node.
Execute AT+SECURITY?<CR> AT+SECURITY=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 1
Range 0 – 1