Manual

60
ProBee
-
ZE20S User Guide Rev.1.
10
OK # Response
AT+REMOTE=0001950000000212,AT+AI2?
# Get routers analog data for temperature from remote coordinator
218F # Router’s analog data for temperature (Refer to 6.6.7 Data
# Conversion)
OK # Response
AT+REMOTE=9AD6,AT+AI3?
# Get routers analog data for illumination from remote coordinator
0D8D # Router’s analog data for illumination (Refer to 6.6.7 Data
# Conversion)
OK # Response
6.6.5 Periodic Sampling – Destination Node
6.6.5.1 Coordinator Configuration
The AT commands for Coordinator Configuration:
ATS11=1 # Set coordinator to receive incoming data
OK # Response
ATZ # Apply configuration
OK # Response
6.6.5.2 Router Configuration
The AT commands for Router Configuration:
AT+DESTLA=0001950000001481
# Set coordinator to the destination device to send
# analog data such as temperature, illumination
OK
ATS42=1 # Period to send analog data to destination (unit : second)
OK # Response
ATS43=0 # Set destination to AT+DESTLA
# ATS43=1 sets destination to sink node
ATZ # Apply configuration
OK # Response
6.6.5.3 Temperature / Illumination Data at Coordinator
The AT commands for Sampling Temperature / Illumination at Coordinator:
++0001950000000212|11000000000**0000|****,****,21D6,0C72,****,****