User guide

44
ProBee
-
ZS10 User Guide Rev.1.
1
.1
available remote command by “AT+REMOTE<CR>”.
Execute AT+REMOTE=<addr>,<cmd>?<CR> AT+REMOTE=<addr>,<cmd>=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
5.8 UART
5.8.1 AT+BAUDRATE or AT+UB
Description
Get/Set the serial port speed for communication between the module serial port and
host.
Execute AT+BAUDRATE?<CR> AT+BAUDRATE=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 9600
Range 300 - 230400
5.8.2 AT+DATABIT or AT+UD
Description Get/Set the serial data bit setting on the module.
Execute AT+DATABIT?<CR> AT+DATABIT=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 8
Range 7 - 8
5.8.3 AT+PARITY or AT+UP
Description Get/Set the serial parity setting on the module.
Execute AT+PARITY?<CR> AT+PARITY=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 0
Range 0 - 2
5.8.4 AT+STOPBIT or AT+US
Description Get/Set the serial stop bit setting on the module.
Execute AT+STOPBIT?<CR> AT+STOPBIT=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default 1
Range 1 - 2