PromiESD01/ESD02™ User Manual Ver. 2.0.0 (2006.02.2) by Bluetooth Enabling Wireless Serial Communications Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Products 2 Promi-SD/ESD Series Bluetooth Serial Adapter ESD01 Part Number ESD02 IP11-320 SD101 IP11-321 SD202 IP10-300 SD205 IP10-301 IP10-302 Description Board-type wireless serial adapter with MMCX antenna connector Board-type wireless serial adapter with onboard antenna External type wireless serial adapter with internal battery External type wireless serial adapter External type wireless serial adapter with dip switch Power Class Class1 Class2 Class2 Cla
Promi-ESD User Manual – Products 3 Promi-MSP Series MSP102B MSP102A Wireless MultiSerial Adapter Part Number IP20-400 IP20-401 Wireless multi-serial adapter COM port redirector supported Serial/IP Wireless multi-serial adapter COM port redirector supported Serial/IP Up to 7 links simultaneously Up to 14 links simultaneously Power Class Class1 Class1 RF Range Up to 100m Up to 100m Power Connector DC plug DC plug Power supply 5V 5V Serial connector Male DB9 Male DB9 Serial Inter
Promi-ESD User Manual – Products 4 Accessories Antenna Power Supply Extension Cable SAT DAT PAT EAT IA60-800 IA60-801 IA60-802 IA60-820 Stub (30mm) Dipole (120mm) Patch (1309065mm) Board type (1867mm) ESD01 use only EPA OPA UPA DPA IA70-840 IA70-841 IA70-860 IA70-861 External Power Adaptor Domestic use only External Power Adaptor International use USB power cable DC power cable RFC EEC SPC IA80-880 IA80-881 IA80-882 Antenna extension cable (1m) Antenna extension cab
Promi-ESD User Manual – Table of Contents 5 Table of Contents Before Using the Product Welcome -------------------------------------------------------------7 Copyrights/Certification/Limited Liability ----------------- 7 Precautions and Safety ----------------------------------------- 7 General Terms and Conditions of Sale -------------------- 8 1.
Promi-ESD User Manual – Before Using the Product 6 Before Using the Product Welcome Copyrights/Certification/Limited Liability Precautions and Safety General Terms and Conditions of Sale get UNWIRED, it’s easy! Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Before Using the Product 7 Welcome Thank you for purchasing Promi-ESD products. Promi-ESD is a module for wireless serial communication using Bluetooth technology, the international standard for short range wireless communications. Its interoperability and credibility delivers the maximum benefits of wireless communication. This user manual is designed to help you use the Promi-ESD series properly.
Promi-ESD User Manual – Before Using the Product 8 Do not drop or subject the module to impact. Damage to your products may result from improper use. Keep away from harsh environments including humid, dusty, and smoky areas. Damage to your ESD may result from improper use. Do not place heavy objects on the product. Damage to your products may result from improper use. General Terms and Conditions of Sale 1. GENERAL.
Promi-ESD User Manual – Before Using the Product 9 practicable, refunds to Buyer the purchase price of the affected Products in exchange for their return.
Promi-ESD User Manual – Getting Started 10 1. Getting Started Features of Promi-ESD Components Specifications get UNWIRED, it’s easy! Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Getting Started 11 Features of Promi–ESD Reliability and Interoperability Promi-ESD is a module device for wireless serial communication using the Bluetooth technology that is international standard of short range wireless communications. Promi-ESD accomplishes more reliable wireless communication. As Promi-ESD can communicate with other Bluetooth devices, user may construct various communications with it.
Promi-ESD User Manual – Getting Started 12 Components Stub Antenna Promi-ESD01 Antenna Cable Promi-ESD01 Promi-ESD02 Promi-ESD02 Please check the components of Promi-ESD in Fig. 1-1 when purchasing. The picture of product may differ by models. The components of the package may change for improving product capacity or quality without notice. Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Getting Started 13 Specifications Specification Model name Promi-ESD01 TM Promi-ESD02 TM Input Voltage DC 3V∼3.3V DC 3V∼3.3V Bluetooth Spec Bluetooth™ Specification v1.1 Bluetooth™ Specification v1.1 Transmission Power 16dBm(Class 1) Max +4dBm(Class 2) RF Range Max 100m (Default Antenna) Max 30m (Default Antenna) Baud rate 1200 ∼ 230000bps 1200 ∼ 230000bps Power Consumption 75mA (input DC 3.3V) 48mA (input DC 3.
Promi-ESD User Manual – Configurations 14 2. Configurations Operation Modes Serial Ports PromiWINTM Terminal Program get UNWIRED, it’s easy! Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Configurations 15 Operation Modes In addition to the serial port configurations such as bit/second, data bit, parity, stop bit, flow control, Promi-ESD has some configurations for Bluetooth. For getting the most out of Promi-ESD, user should understand the following Bluetooth connection schemes. A Bluetooth device can play a role as a master or slave. Master tries to connect itself to other Bluetooth device, and slave is waiting to be connected from other Bluetooth devices.
Promi-ESD User Manual – Configurations 16 MODE 2 Promi-ESD is waiting for the connection from the last connected Bluetooth device. Promi-ESD in Mode2 is to be a slave and waiting for the connection only from the last connected Bluetooth device. Just like Mode1, if there is no BD address stored in Promi-ESD, the mode change from other operation modes to Mode2 is not allowed.
Promi-ESD User Manual – Configurations 17 Promi-ESD supports only 8 data bit. In the case of 7 data bit, please contact the technical support. Hardware Flow Control Promi-ESD plugged into its host system transmits data from host to the other side Bluetooth device. These data is saved temporarily in the internal buffer of Promi-ESD and sent repeatedly until the transmission is completed packet by packet.
Promi-ESD User Manual – Configurations 18 Configuration Software Configuration Software Usage Operating Platform PromiWIN Individual setup of PromiESD MS Windows 98SE or higher PromiWIN PromiWIN is a program running on Microsoft Windows for the configuration of Promi-ESD. Install PromiWIN on your computer. Plug a Promi-ESD into the serial port using RS232 jig board and turn on the power. Run PromiWIN. Set each option properly and click [Confirm].
Promi-ESD User Manual – Configurations 19 Serial port settings can be changed by and of PromiWIN in the menu bar at upper left corner of the window without re-running the PromiWIN program. The icons in the left side window come to the corresponding windows. In device configuration window, hardware reset can be executed or operation mode and RS232 can be configured as well. Security option also can be configured in this window.
Promi-ESD User Manual – Configurations 20 Promi-ESD has 4 response messages, ‘OK’, ‘ERROR’, ‘CONNECT’, and ‘DISCONNECT’. In some cases, these responses can affect the host system unexpectedly. To prevent this, user can set the response to ON or OFF. (AT Command) For Promi-ESD, hardware flow control can be configured only by bridge CTS and GND. Thus H/W Flow Control option will not work in this case. Click [Apply] button to reflect the given options to Promi-ESD actually.
Promi-ESD User Manual – Configurations 21 Terminal Program A terminal program is an application that will enable a PC to communicate directly with a modem. If you are using Windows 98SE or higher version of Windows, HyperTerminal program as it is included as part of the operating system. Promi-ESD provides some extended AT commands for its configurations on terminal program. This manual will explain the method using HyperTerminal.
Promi-ESD User Manual – Configurations 22 Choose the settings in File->Properties->Settings->ASCII setup that let you turn echo on in HyperTerminal; this will show the response Promi-ESD sends on the screen. You now get the HyperTerminal window where you are able to control PromiESD with AT commands. For expanded AT commands that Promi-ESD provides, please refer to Appendix A. AT commands.
Promi-ESD User Manual – Connections 23 3. Connections Promi-ESD Pin Assignment get UNWIRED, it’s easy! Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Connections 24 Promi-ESD Pin Assignment Pin Assignment (Promi-ESD01) NC Status DSR DTR RST GND 7 8 9 10 11 12 1 2 3 4 5 6 CTS VDD GND TXD RXD RTS Pin no. Pin name Direction Description Signal Level 1 GND I Power Ground Ground 2 TXD O UART data out TTL 3 RXD I UART data input TTL 4 RTS O UART Ready to Send TTL 5 CTS I UART Clear to Send TTL 6 VDD I DC input (3.0 ~ 3.
Promi-ESD User Manual – Connections 25 Pin Assignment (ESD02) Antenna GND 1 8 RXD VDD 2 7 TXD Status 3 6 RTS RST 4 5 CTS Pin no. Pin name Direction Description Signal Level 1 GND I Power Ground Ground 2 VDD I DC input (3.0 ~ 3.
Promi-ESD User Manual – Connections 26 Connection Module low signal RST(Reset) : RST signal will be used for initialization of Promi-ESD. RST should be on 0V status for at least 1 second for this. Promi-ESD01 When TTL level of MICOM is 3.3V MICOM MICRO-VDD PROMI-ESD01 DC 3.3V VDD MICOM-DCD Status MICOM-TXD RXD MICOM-RXD TXD MICOM-RTS CTS MICOM-CTS RTS MICOM-DTR DSR MICOM-DSR DTR MICOM-RST RST MICOM-GND GND When TTL level of MICOM is 3.3V and not using hardware flow control.
Promi-ESD User Manual – Connections 27 MICOM MICRO-VDD PROMI-ESD01 DC 3.3V VDD Status MICOM -TXD RXD MICOM -RXD TXD CTS RTS DSR DTR MICOM -RST RST MICOM -GND GND When TTL level of MICOM is 5V MICOM MICRO-VDD PROMI-ESD01 DC 3.3V VDD MICOM-DCD Status 68K 115K MICOM-TXD RXD MICOM-RXD TXD 68K 115K MICOM-RTS CTS MICOM-CTS RTS 68K 115K MICOM-DTR DSR MICOM-DSR DTR 68K 115K MICOM-RST RST MICOM-GND GND Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Connections If you are using Reset. Promi-ESD02 When TTL level of MICOM is 3.3V Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Connections MICOM MICRO-VDD 29 PROMI-ESD02 DC 3.3V VDD MICOM-DCD Status MICOM -TXD RXD MICOM-RXD TXD MICOM -RTS CTS MICOM -CTS RTS MICOM -RST RST MICOM-GND GND When TTL level of MICOM is 3.3V and not using hardware flow control MICOM MICRO-VDD PROMI-ESD02 DC 3.3V VDD Status MICOM-TXD RXD MICOM-RXD TXD CTS RTS MICOM-RST RST MICOM-GND GND When TTL level of MICOM is 5V Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Connections MICOM MICRO-VDD 30 PROMI-ESD02 DC 3.3V VDD MICOM-DCD Status 68K 115K MICOM-TXD RXD MICOM-RXD TXD 68K 115K MICOM-RTS CTS MICOM-CTS RTS 68K 115K MICOM-RST RST MICOM-GND GND Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Trouble Shooting 31 4. Trouble Shooting get UNWIRED, it’s easy! Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Trouble Shooting 32 No Data Transmission COM Port Settings Check whether the Baud rate of Promi-ESD is same as that of its host equipment. If you do not know the current Baud rate of Promi-ESD, initialize it to 9600 by pressing Reset. Check whether the Data bit is set to 8. Promi-ESD supports only 8 Data bit. If your host equipment uses 7 Data bit and even or odd parity, it can work as if it uses 8 Data bit and No parity. This is valid only when both DCE devices are Promi-ESD.
Promi-ESD User Manual – Trouble Shooting 33 It takes 30msec approximately for a Promi-ESD to complete the data transmission to the other side Bluetooth device. This time delay cannot be reduced and would be bigger as the RF transmission environment is bad. Do not use Promi-ESD If your applications cannot allow this time delay.
Promi-ESD User Manual – Specifications 34 5. Specifications Bluetooth Interface Power Mechanical Dimensions Environmental Default Antenna VDD Power Consumption Wireless Coverage get UNWIRED, it’s easy! Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Specifications 35 BLUETOOTH Bluetooth Interface Bluetooth 1.1 specification compatible and qualified Protocol: RFCOMM, L2CAP, SDP Profiles: Serial Port Profile Radio Frequency: 2.4 ~ 2.4738GHz Number of Channels: 79 Transmission Power Class 2 (Promi-ESD02) Transmission Power Class 1 (Promi-ESD01) Data Transmission Rate: 380Kbps Max. UART Interface Output Interface UART Connector: 2.54mm Header 2x6 (ESD01), 2.
Promi-ESD User Manual – Specifications 36 Mechanical Dimensions Promi-ESD01 Promi-ESD02 Environmental Recommended Operational Temperature: -20℃ ~ 70℃ Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Specifications 37 Recommended Operational Humidity: 90% Max. Non-condensing Default Antenna (ESD01 default, ESD02 option) Type: Helical Frequency: 2,400 ~ 2,485GHz Gain: Max. 1dBi ±1 Impedance: 50Ω size: 30mm9mm (WD) weight: 3.5g Power Consumption Recommended Operating Conditions Operating Condition Min Max Operating Temperature Range -20°C 70°C VDD 3.0V 3.6V For safe operation, supply power of 3.3V.
Promi-ESD User Manual – Specifications 38 Output Voltage Input VOL output logic level low (lO = 4.0mA) - - 0.2 V VOH output logic level high (lO = -4.0mA) VDD-0.2 - - V Wireless Coverage The table below shows the average measuring results in open space. These results can vary according to the environmental conditions.
Promi-ESD User Manual – Appendix A AT Commands A-1 Appendix A. AT Commands Terminology Command Category Command Description Command Validity get UNWIRED, it’s easy! Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Appendix A AT Commands A-2 Terminology AT Command AT command set is the de facto standard language for controlling modems. The AT command set was developed by Hayes and is recognized by virtually all personal computer modems. Promi-ESD provides the extended AT command set to control and configure the serial parameters and Bluetooth connection. AT Response Promi-ESD replies to AT commands with 4 kinds of message, ‘OK’, ‘ERROR’, ‘CONNECT’ and ‘DISCONNECT’.
Promi-ESD User Manual – Appendix A AT Commands A-3 to Timeout in second Command Category Command Category RESET ATZ 2 AT&F 3 AT 4 AT+UARTCONFIG,b,p,s 5 AT+BTINFO? 6 AT+BTINQ? 7 AT+BTLAST? Mode 8 AT+BTMODE,n Status 9 +++ Information Connection Security Miscellaneou s S-REGISTER AT commands 1 SERIAL PORT BLUETOOTH Index 10 AT+SETESC,nn 11 ATO 12 AT+BTCANCEL 13 AT+BTSCAN 14 AT+BTSCAN,n,to 15 AT+BTSCAN112233445566 ,to 16 ATD 17 ATD112233445566 18 ATH 19 AT+BTK
Promi-ESD User Manual – Appendix A AT Commands A-4 28 ATSnn=mm Command Description 1 ATZ Response OK Purpose Software Reset Description This is the same effect as power off and on. This command disconnects Bluetooth device, and stops ongoing task. After rebooting, the status is decided by the preset operation mode. Some AT commands need ATZ to take effect.
Promi-ESD User Manual – Appendix A AT Commands A-5 Purpose Set Serial parameters Parameters Baudrate= 1200/2400/9600/14400/19200/38400/57600/115200/230 400 (Default=9600) Parity=N/E/O (Default=N) Stopbit=1/2 (Default=1) Description The Serial parameters can be set or changed. The factory default is 9600, N, 1. To take effect of this command, ATZ or power off and on.
Promi-ESD User Manual – Appendix A AT Commands A-6 Description The Bluetooth devices in Inquiry scan mode nearby are displayed with their BD addresses, Device names, and Class of device. Maximum 10 devices are scanned for 30 seconds. Reference AT+BTSCAN, ATD, AT+BTINFO? 7 AT+BTLAST? 112233445566 Response OK Purpose Display the BD address of the last connected device Description The Bluetooth device connected to this Promi-ESD last time is displayed with its BD address.
Promi-ESD User Manual – Appendix A AT Commands A-7 other side Bluetooth device, and any AT command is not accepted but this command, which is not echoed on the screen. When Promi-ESD encounters a character ‘+’ from host, it stops the data transmission and waits for next 2 characters. If the next 2 characters aren’t both ‘+’, it restart to transmit data including the first ‘+’ as well. If not, it converts the operation status to ‘Standby’.
Promi-ESD User Manual – Appendix A AT Commands A-8 Purpose Terminate a current executing task Description This terminates a current executing task, such as Inquiry scan and Page scan, then converts the operation status to ‘Standby’. Reference AT+BTSCAN, ATD, AT+BTINQ? 13 AT+BTSCAN OK Response CONNECT 112233445566 Purpose Wait for inquiry and connection from other Bluetooth devices Description This allows the inquiry and connection from the other Bluetooth devices.
Promi-ESD User Manual – Appendix A AT Commands A-9 of to is 0, it will wait forever. When connection is made with other Bluetooth device, SD response will be ‘CONNECT’ with its BD address. If there is no connection made within this time duration, SD response is ‘ERROR’ and the operation status becomes to ‘Standby’.
Promi-ESD User Manual – Appendix A AT Commands A-10 Purpose Connect to the last connected Bluetooth device Description Promi-ESD saves the BD address of the Bluetooth device most recently connected. ATD can make connection to it without input its BD address. If it fails to make connection, SD response is ‘ERROR’.
Promi-ESD User Manual – Appendix A AT Commands A-11 Purpose Change pin code Parameters $string= New pin code (Default=”1234”) Description Pin code is a string, which allows 16 alpha-numeric characters maximum. Based on this pin code, Promi-ESD generates a link key which is used in actual authentication process.
Promi-ESD User Manual – Appendix A AT Commands A-12 Parameters n=0: Inactivate (Default) n=1: Activate Description If n is set to 1, Promi-ESD asks pin code every time of connection. This is used to level up the security.
Promi-ESD User Manual – Appendix A AT Commands A-13 Parameters n=0: Inactivate (Default) n=1: Activate Description During no data transmission, Promi-ESD can be in low power mode to save the power consumption. It takes a few seconds to wake up Promi-ESD in low power mode. 26 AT&V S0:m0;S1:m1; …Sn:mn Response OK Purpose Display all the S-register Description All parameters are stored at S-register in flash memory. These values are sustained until hardware reset.
Promi-ESD User Manual – Appendix A AT Commands A-14 Command Validity AT Command Standby Pending AT ○ ○ ATZ ○ ○ AT&F ○ ○ AT+BTINQ? ◎ ATD112233445566 ◎ ATD ◎ AT+BTSCAN ◎ AT+BTSCAN,n,to ◎ AT+BTSCAN112233445566,to ◎ AT+BTCANCEL Connect ○ +++ ○ AT+SETESC ◎ ATO ● ATH ● AT+BTSEC,Auth,Encr ◎ AT+BTLAST? ○ AT+BTMODE,n ◎ AT+BTNAME="Name" ◎ AT+BTKEY="nnnn" ◎ AT+BTINFO? ○ AT+BTLPM,n ◎ AT+BTSD? ○ AT+BTCSD ◎ AT+BTFP,n ◎ AT+UARTCONFIG,b,p,s ◎ ○ ○ ○ ◎ Valid only
Promi-ESD User Manual – Appendix A AT Commands A-15 Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Appendix B S-Register B-1 Appendix. B S-Register get UNWIRED, it’s easy! Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Appendix B S-Register B-2 S-Register S-registers contain 46 parameters of Promi-ESD. These are stored in flash memory and sustained the values unless hardware reset is executed. The value of S-register can be accessed and changed with ATS command by user. Some S-registers not shown below are set to maximize the performance of PromiESD. Thus it is not recommended to change these S-registers. Change the value of S-register only in Standby status.
Promi-ESD User Manual – Appendix B S-Register B-3 S12=0, Promi-ESD does not clear the data buffer received from host system when disconnected. S12=1, Promi-ESD clears the data buffer when disconnected. S14: Enable DTR Transfer (default 1, ESD01 only) S14=0, DTR/DSR signal is transferred to loop-back. S14=1, DTR signal is transferred to DSR of remote device. S15: Enable Disconnect by DTR (default 0, ESD01 only) S15=0, DTR signal cannot release the connection.
Promi-ESD User Manual – Appendix B S-Register B-4 S46: BD Address of Last Connected Device This saves the BD address of the Bluetooth device connected most recently. Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Appendix.C RS232 interface Jig Board C-1 Appendix. C How to make a RS232 interface Jig Board get UNWIRED, it’s easy! Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Appendix.C RS232 interface Jig Board How to make a RS232 interfaced Jig Board Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Appendix.D Technical Support D-1 Appendix D. Technical Support get UNWIRED, it’s easy! Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Promi-ESD User Manual – Appendix.D Technical Support D-2 Use this form to request technical support for Promi-ESD. Individual form should be filled out for each Promi-ESD in question. Referring to the example on separate sheet, please provide as much information as possible so we may resolve and respond to your inquiry promptly. When you have finished, submit this form by e-mail to support@sena.com or by fax to +82 2 573-7710. NOTE: Before you contact technical support, please have a look at our FAQ.
Promi-ESD User Manual – Appendix.
Promi-ESD User Manual – Appendix.D Technical Support D-4 * Distance is a linear distance between Promi-ESD and the other side Bluetooth device. ** Obstacles are things affecting RF performance in the middle of Promi-E SD and the other side Bluetooth device, such as walls, partitions, other equipments, etc. Copyright © 2006 Sena Technologies, Inc. All rights reserved.