Owner manual
Promi-ESD User Manual – Appendix A AT Commands
A-13
Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Parameters
n
=0: Inactivate (Default)
n
=1: Activate
Description During no data transmission, Promi-ESD can be in low
power mode to save the power consumption. It takes a
few seconds to wake up Promi-ESD in low power mode.
26 AT&V
Response S0:m0;S1:m1; …Sn:mn
OK
Purpose Display all the S-register
Description All parameters are stored at S-register in flash memory.
These values are sustained until hardware reset.
Reference ATS
27 ATSnn?
Response value
OK
Purpose Display a given S-register
Parameters
nn=
Address of S-register
Description A specific S-register is displayed.
Reference AT&V
28 ATSnn=mm
Response OK
Purpose Change S-register value
Parameters nn= Address of S-register
mm= New value of S-register
Description Some S-registers are optimized for the overall
performance and protected from an arbitrary change by
user. When users try to change these S-registers, SD
response is ‘ERROR’.
For details of S-register, refer Appendix. B.
Reference AT&V
Example ATS10=0