User's Manual

2.4.2. Access Control
The Access Control section allows conguration of how the AN100/300 can be accessed.
Figure 24. Access Control
Path Settings, Security
Parameters
• HTTPPort– Enter device web server port to connect. DEFAULT: 80
PRO TIP: A port number, other than the default, can be assigned to enable remote access to the AN100/300 via port
forwarding on the network router.
• WebAccess– Select Enable or Disable to enable or disable the ability to modify the device via Web Browser.
DEFAULT: Enable
CAUTION: Disabling web access will cause lost connectivity to the AN100/300 web interface. If this should occur, the
only way to regain this connectivity is to restore the hardware factory default settings. (Press AN100/300 Reset button
for 10 seconds.)
• Telnet– Select Enable or Disable to enable or disable the ability to modify the device via a command line interface (CLI)
through a telnet session. DEFAULT: Enable
• SSH– Select Enable or Disable to enable or disable the ability to modify the device via a command line interface (CLI)
with a secure channel. DEFAULT: Disable
Configuration Instructions
To congure Access Control:
1. Click Settings, Security.
2. Specify the Access Control Settings.
3. Click Save.