User Manual

MI002953-E
ENGLISH - 1/4
MI002953-E
ENGLISH - 3/4
MI002953-E
ENGLISH - 2/4
MI002953-E
ENGLISH - 4/4
EN
T Series - Loop powered in-field converters
Overall description
The T201DCH100 and 300 are isolated, contact less loop powered AC/DC current
transducers. The look and device’s function are very similar to those of an active
standard Current Transformer, but with the remarkable feature of measuring the
TRMS DC and AC component or DC bipolar of the current. For its electrical endurance,
ease of use and compact dimensions, the T201DCH100 and 300 fit every kind of current
measurement: up to 100 Adc/Aac and 300 Adc/Aac (respectively).
This document is property of SENECA srl.Duplication and reproduction are forbidden,if not authorized.Contents of
the present documentation refers to products and technologies described in it. All technical data contained in the
document may be modified without prior notice. Content of this documentation is subject to periodical revision.
OPERATING CONDITION
Protection index IP20.
Temperature -20 +65 °C.
Storage Temperature -40 +85 °C.
Humidity 10 90 % non-condensing.
Altitude Up to 2000 m a.s.l.
CASE
Weight
47 g.
Overall dimensions 96,5 x 68 x 26 mm (without terminals).
Box material PBT, black
STANDARDS
Standards
EN61000-6-4 (electromagnetic emission, industry).
EN64000-6-2 (electromagnetic immunity, industry).
EN61010-1 (safety).
Mounting
The device can be located in any position and place, in accordance with the operating
conditions above stated. Use the included holder bracket when fixing to a DIN rail.
WARNING
: High-strength static magnetic fields may change the output value: let avoid
closeness to permanent magnets, electromagnets or iron bulks that cause such a modifi-
cation of the surrounding magnetic field; try a different arrangement or orientation if zero-
error was greater than expected.
Multi-turn primary winding to improve sensibility
You can increase the sensibility of the device passing several times trougth the hole with
the measuring current cable, realizing turns with multiplicative effect: e.g. passing 5
times trougth the hole, as to see 4 turns,choosing a 100A range, you get an equivalent
sensibility of 20 A full-scale. When you make this, let dispose the turns with symmetry in
order to preserve accuracy: use diametric contraposition with 2 turns, cross disposition
with 4 turns, and so on.
Disposal of electrical & electronic equipment (applicable throughout the EU and other countries wit separate collection programs). This symbol, found on your product or on
its packaging, indicates that this product should not be treated as household waste when you wish to dispose of it. Instead, it should be handed over to an applicable collection
point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences to the
environment and human health, which could otherwise be caused by inappropriate disposal of it. The recycling of materials will help to conserve natural resources. For more
detailed information about the recycling of this product, please contact your local city office, waste disposal service or the retail store where you purchased this product.
Key features
HW
Similar usage to a standard alternating current active C.T.
No shunt, no wasted power from the measure circuit.
High accuracy rating: AC:0.5%, DC:1%.
Suitable for use with all Seneca modules that allow to power the
T201DCH100 and 300 with at least 12 Vdc and having a 0 10Vdc input
Two ranges, dip-switch selectable.
Damping filter availability to improve stable reading.
Suitable for batteries , battery chargers, solar panels, power units and
generic dc and ac loads.
Compact size: overall dimensions less than 96,5 x 68 x 26 mm.
T201DCH100 T
-
201DCH300
Contact-less direct and alternating
TRMS current transducer or direct BIPOLAR
P.S.=power supply
Vout= 0 10V outputC
N.c.=no connected
+
+
P.S.
V
+
+
11.5 28 VC
Vcc
Vout
Gnd
N.c.
Included accessories for DIN rail mounting
In the table, the symbol refers to switch in ON position; the factory setting of the device is:
- range up to: 100A (T201DCH100) and 300A (T201DCH300); - filter selected for 800ms
and / TRMS Mode selected.C A
12 bit (4000 points)
Technical features
INPUT
Limit values
0 100A / TRMS or -100 +100A Bipolar for DCH100C A _ C
0 300A Bipolar for DCH300C A _ C/ TRMS or -300 +300A
Hole diameter
20.8 mm
Ranges
0 50 or 0 100A TRMS;-50 +50 or -100 +100A Bipolar_
0 300 or 0 150A TRMS;-150 +150 or -300 +300A Bipolar_
(selected by dip-switches)
Insulation
OUTPUT AND POWER SUPPLY
Type
0 10 V , min load R =2 k . The output has the negativeC
LOAD
Ω
Connections
Removable screws pitch 5.mm for max 2.5mm² cables
Power supply
11.5 28Vdc (between Vcc and GND)
Protections
- Polarity reversal
- Over-temperature.
Absorption
21 mA (with no load)
ACCURACY
Temperature coefficient < 200 ppm/°C.
EMI error
< 0.5%
Response Time
- Filter «fast»: 800 ms
- Filter «slow»: 2000 ms.
Type of measure
C A C/ TRMS or Bipolar
Peak factor
2
Pass band
2.5kHz
Resolution
Accuracy class
(over the 2% of end
scale)
Accuracy class
(under the 2% of end
scale)
Hysteresis on the
measurement
0.15% of end scale
Overload
2000 A impulsive, 300 A continuous
in common with power supply. Screws: Vout and GND
SENECA s.r.l.
Via Austria, 26 35127 PADOVA ITALY
Tel. +39.049.8705355 - 8705359 - Fax +39.049.8706287
Manuals and configuration software are available at www.seneca.it
Range
Accuracy A
Accuracy C
100 A o 300 A
0.5% of end scale.
1% of end scale.
50 A o 150 A
1% of end scale.
2% of end scale.
Range
Accuracy A
Accuracy C
100 A o 300 A
1% of end scale.
2% of end scale.
50 A o 150 A
2% of end scale.
4% of end scale.
DON’T USE BARE CONDUCTORS;
The insulated cable ensures double insulation
up to 300 V CAT II (to Earth).
DIP-switches
Range
Filter (10% 90%)
Mode
Not Used
1
2
DCH100 - 300
3
DCH100 - 300
4
Filter = 800ms
C A/ TRMS
X
l
l
Filter =2000ms
l
C Bipolare
l
X
TRMS
Input (A)
T201DCH100
T201DCH300
10
0
±100
±300
±50
±150
5
-100
+100
0
-300
+300
10
5
Input (A)
Bipolar
Output (V)
Output (V)
+50
+150
-50
-150
Settings:
(see manual)
E 004071T
AC/DC TRMS current transducer
SENECA
Gnd
N.C.
Vcc
Vout
Made in ITALY
T201DCH100
T201DCH300
100A
300A
Filter
Range
On
4
3
2
1
S1
Mode

Summary of content (1 pages)