Instruction manual

SENKO cookers 2P extra rustik and glass Instruction manual 16
odvijačem skinite
zaštitni poklopac
Remove the external protective
lid with a screwdriver
Remove the sheet beneath the
lid by pressing onto the
weakest juncture
Install the sliding rosette by using
bolts previously used to attach
the inner protective lid
Install the external protective sheet
by using bolts previously used to
attach the external protective lid
figure 8
Mount the protective lid onto
the remaining chimney
opening!
Remove the internal protective
lid with a screwdriver
Connect the cooker to the chimney using a sliding rosette, 150 mm in
diameter. Specially designed sliding rosette enables the adjustment of the
chimney opening in tolerance of 1,5 cm upwards, i.e. downwards.
In case it is necessary to keep the cooker removed from the chimney
opening, use the standard smoke outlet pipe, 150 mm in diameter. It is not
allowed to reduce the prescribed pipe diameters !
If the cooker is further removed from the chimney opening, it is
connected via extension tube and an elbow. The extension smoke inlet
pipe must have an appropriate incline and must not exceed 125 cm in
length. The connection of the chimney and the smoke inlet pipe must be
completely fastened !
4.4. FRESH AIR VENTS
The room where the cooker is installed must be provided with
sufficient air inflow to ensure combustion. The area must be regularly
ventilated.