Instruction manual

SENKO cookers 2P extra rustik and glass Instruction manual 37
8. MALFUNCTIONS / CAUSES / SOLUTIONS
PROBLEM
POSSIBLE CAUSE
SOLUTION
Firebox door glass is
black and/or the firebox
is smoky (black soot)
insufficient flue
draught (less than
10Pa)
faulty regulation
too much fuel in the
firebox
fuel too moist
inadequate fuel
excessive firebox
temperature
check the connection of the cooker
with the chimney and the chimney
study chapters 4.2 and 4.3.
study chapter 5.2.
reduce the fuel quantity
use fuel with less than 17% of
relative moisture
use fuel as described in chapter 1.1.
reduce the fuel quantity and primary
air volume and adjust chimney flue
draught in accordance with chapter 5.2
There is noise from the
boiler
insufficient water
level in the central
heating system
insufficient water
pressure in the central
heating system
improper central
heating installation
during the summer
period, the boiler is not
connected to the water
heating boiler
the cooker is not
placed in a horizontal
position with the use of
spirit level
excessive velocity of
water flow in the
system
refill the central heating system with
the necessary amount of water to
achieve 2.5 bar pressure
increase water pressure to 2,5 bar
execute the central heating
installation in accordance with
professional standards and DIN 4751
norm - part 1 for open systems, i.e.
4751 part 2 for closed systems
connect the boiler to water heater
mount the cooker as described in
chapter 4.1.
reduce the water circulation velocity
by adjusting the number of pump
rotations
Insufficient flue draught
in the chimney; black
smoke expelled from
the chimney
chimney filled with
soot
cooker filled with
soot
chimney partially
clogged or filled with
soot
fuel not sufficiently
dry
firebox cast grate
turned in the wrong
clean the chimney
clean the cooker
unclog and clean the chimney
use fuel in accordance with chapter
1.1.
set the grate in accordance with
chapter 5.3.
close the door