User's Manual

Prepared 10/2016 16 Patent pending
14407 Coil Plus Dr, Unit A | Plaineld, IL 60544
www.sennco.com | techsupport@sennco.com
815.577.3400 | Toll free 866.736.6261
Mon - Fri 9AM - 5PM CST
D. Security Perimeter Domes
1. Plug the barrel plug end of the power cable into the power port on the Security Perimeter Dome.
2. Plug the power cable into an outlet that has AC power available.
3. The green LED on the front of the Security Perimeter Dome indicates power is being received.
4. Place the Security Perimeter Dome in posion. (Note: They cannot be placed upside down. )
a) Each Security Perimeter Dome generates a 6  - 8  radius sphere within which the protected devices are safe.
b) Addional Security Perimeter Domes within the same xture should be spaced no more than 3 1/2 feet apart.
c) Each Security Perimeter Dome has an arrow on the front. All Security Perimeter Dome arrows in the system need to point in the
same direcon.
d) Mulple Security Perimeter Dome signals overlap to form a security area as illustrated below.
Place Security Perimeter Domes in clear line of sight within 3 1/2 feet of each other and within 3 feet of the farthest cradle. Avoid mounng
Security Perimeter Domes near the oor or with large metal objects, metal cabinets, other equipment, etc. in close proximity or between the
Security Perimeter Domes and the cradles. If Security Perimeter Domes are mounted below the xture, do not mount them more than 2 feet
below the cradles.
The blue LED on the front of the Security Perimeter Dome indicates wireless signals are being received. Aer the system is set up and the Main
Alarm is powered, the blue LED should ash once about every second to indicate proper operaon.