User's Manual

Prepared 10/2016 20 Patent pending
14407 Coil Plus Dr, Unit A | Plaineld, IL 60544
www.sennco.com | techsupport@sennco.com
815.577.3400 | Toll free 866.736.6261
Mon - Fri 9AM - 5PM CST
V. Reseng the system
A. Make sure that the Main Alarm has power, all Security Perimeter Domes have power (indicated by a green LED), all of the cradles have pow-
er (indicated by a red LED on the underside of the cradle), and that all of the sensor heads have been acvated by placing them on a pow-
ered cradle (indicated by two red ashing LEDs on the sensor head).
B. Make sure that the Security Perimeter Domes are spaced no more than 3 1/2 feet apart with all of their arrows pointed in the same
direcon. Make sure each cradle is within 3 feet of a Security Perimeter Dome and within 50 feet of the Main Alarm. Make sure that near-
est sensor head is at least 2 feet away from the Main Alarm.
C. Insert a recognized DaKey into the Main Alarm and leave it inserted.
D. The Security Perimeter Domes will all begin to ping a signal back to the Main Alarm (indicated by a blue ashing LED on each Security
Perimeter Dome).
E. The LCD will state “DIS-ARMED”
F. Hold down the buon on the front of the Main Alarm unl the LCD states, “RELEASE TO RESET.” (Approximately 4 seconds)
G. The LCD will state “RESETTING” and show a device count of 000.
H. The Main Alarm will listen for all of the sensor heads and the device count on the LCD will be updated.
I. When completed, the LCD will state “RESET” and show a count of the total number of sensor heads found. If this number is less than the
physically present heads check all of them and then repeat the reset.
J. The LCD will also state “Remove key to arm the system” indicang it is now safe to remove the DaKey from the Main Alarm.. The system is
not armed unl the DaKey has been removed.
K. Aer removing the DaKey there will be a less than 5 second delay before the system is armed. The Security Perimeter Domes willash a
blue LED and the sensor heads will ash a green LED as they ping back to the Main Alarm each second.