Product Info

10 | Digital 9000
Accupacks
BA 60 BA 61
Charging capacity 1600 mAh 2000 mAh
Output voltage 3.7 V 3.7 V
Nominal energy 5.9 Wh 7.4 Wh
L 60
Input voltage 12 - 15 V $
Input current max. 900 mA
Pin assignment of DC input
hollow jack socket
Charging voltage max. 4.2 V $
Charging current max. 2 x 1,000 mA
Charging principle • CC CV method (Li-Ion charging method)
• Deep discharge recovery charge
• Capacity monitoring
• Accupack temperature monitoring
• Over/undercharge detection
• Charging time limit (approx. 8 hours)
Compatible Sennheiser
accupacks
• BA 60 (3.7 V, 1,600 mAh, Li-Ion)
• BA 61 (3.7 V, 2,030 mAh, Li-Ion)
Charging time with a completely discharged accupack and at room tempe-
rature (approx. 20 °C/68° F):
• 100 %= approx. 180 min
• 70 % = approx. 60 min
• automatic security switch-off after approx. 8 hours
Dimensions (W x D x H) approx. 80 x 87 x 62 mm
Weight (without mains unit) approx. 160 g
Temperature Operation:
Storage:
0 °C to +35 °C, with reduced charging pow-
er: 0 °C to +45 °C
-20 °C to +70 °C
Relative air humidity Operation:
Storage:
25 % to 95 % (non-condensing)
5 % to 95 % (non-condensing)
Dripping and splashing liquids The product must not be exposed to dripping and splashing
(IP2X)
575838_0818_A01_TD_Digital9000_PRT.indb 10 18.02.2019 12:33:39