ADN System Instruction Manual

Table Of Contents
Configuring the conference system via the central unit
102 | ADN Digital Conference System
Checking the system and detecting errors –
System Menu
The “System” submenu provides information on the current status of your confer-
ence system and any errors that have occurred.
After switch-on, the central unit automatically performs a self-test. If errors are
detected during the self-test, the error icons to indicate the type of error
encountered. When the error icons and appear, and severe errors have
occurred, the display panel changes from orange to red. If severe cabling errors are
detected during the self-test, an error message appears, the display panel lights up
red and the conference system is not operational. For more information on severe
cabling errors, refer to page 62 and page 67.
The central unit also checks the conference system for errors during a running con-
ference and, if necessary, shows the following icons to indicate these errors.
When the error icons and appear and the error concerns the PORT socket of
an ADN PS power supply, the PORT status LED or of the affected ADN PS
f
l
ashes orange.
To ensure trouble-free operation of your conference system:
Carry out the following steps before starting the conference.
T
h
is allows you to diagnose and remedy errors in your conference system at an
early stage.
Set up your entire conference system.
If you do not yet know the fi
nal number of participants, take the largest possi-
ble number of participants as a starting point. Connect the corresponding num-
ber of conference units to the central unit.
If applicable, switch on all wireless conference units so that they can connect to
the antenna module.
First switch on all ADN PS power supplies and then switch on the ADN CU1 cen-
tral unit.
Th
e ADN CU1 central unit performs the self-test and also tests the cabling of
the ADN PS power supplies as well as all wireless conference units that are con-
nected to the antenna module.
If an error or a warning occurs, proceed as follows:
Eliminate the error (see the following tables).
Icon Meaning
Warning triangle
Short-circuit icon
Cable fault icon
Structural change icon
K
N
M
N
Direct Access
30 D1/C1
22
M
N
L
K
ADN PS
3
4
Status information and errors during wireless operation can be monitored
using the “Conference Manager” software (see page 208).
M
N
3
4
During the self-test, do not press any keys or buttons and do not change
the set up of the conference system.
If the number of participants increases after an error-free self-test, we
strongly recommend you to perform a new self-test before starting your
conferenc
e.