ADN System Instruction Manual

Table Of Contents
Putting the conference system into operation
64 | ADN Digital Conference System
Ring topology connected to
different PORT sockets of
an ADN PS power supply
Ring topology connected to
different ADN PS power supplies
A ring topology cannot be connected to different PORT
sockets of an ADN PS power supply.
The error message “Error 60005 Ring cabling between
port I+II” appears on the display panel of the ADN CU1
centra
l unit. The display panel lights up red.
On the ADN PS power supply, the respective status LED
for the PORT I and PORT II outputs in question flashes
orange.
T
o
eliminate the error:
Set up the conference syst
em correctly (see
page
58).
Switch the conference system on again (see
page
77
).
PORT I
12
PORT II
12
ADN PS
A ring topology cannot be connected
to different PORT sockets of two
different ADN PS power supplies.
The error message “Error 60006 Ring
ca
bling between two PS” appears on
the d
isplay panel of the ADN CU1
central unit. The display panel lights up
red.
On the two ADN PS power supplies, the
respective status LED for the PORT out-
p
u
ts in question flashes orange.
To eliminate the error:
Set up the conference system cor-
rect
ly (see
page 58).
Switch the conference system on
again (see
p
age 77).
PORT I
12
PORT II
12
PORT I
12
PORT II
12
ADN PS
ADN PS