ADN System Instruction Manual

Table Of Contents
Putting the conference system into operation
68 | ADN Digital Conference System
ADN-W AM antenna module
connected to the DATA socket of the
ADN PS power supply
Wrongly connected
ADN-W AM antenna module
in the cable ring
No antenna module must be connected to the DATA
PS output socket of an ADN PS power supply.
The error message “Error 60010 AM at PS cascading
port” app
ears on the display panel of the ADN CU1
central unit. The display panel lights up red.
To eliminate the error:
Set up the conference system correctly (see
page 66
).
Switch the conference system on again (see
page 77).
ADN-W AM
CU/PS
PS
DATA
ADN PS
The input socket and the output socket
on the antenna module in the cable ring
have been accidentally swapped.
The antenna module connected in the
cable ring does not function and is not
displayed in the ADN CU1 central unit’s
“System Menu”.
To eliminate the error:
Set up the conference system cor-
rect
ly (see
page 66).
Switch the conference system on
again (see p
age 77).
PORT I
12
ADN PS
IN OUT IN OUT
IN OUT