KA_ADN-PS_543374_0911_SP13.book Seite 1 Mittwoch, 31. August 2011 12:23 12 Contents Contents Information on this quick guide ................................................................................ 2 The ADN PS power supply ........................................................................................... 2 Delivery includes .......................................................................................................... 2 Components required for operation .......................
KA_ADN-PS_543374_0911_SP13.book Seite 2 Mittwoch, 31. August 2011 12:23 12 Information on this quick guide Information on this quick guide Please make sure to read the “Safety information” supplement included separately with the product. This supplement contains important information on the safe operation of the product as well as the manufacturer’s declaration and warranty notes. A detailed instruction manual for the overall ADN conference system can be found www Manual • on the Internet at www.
KA_ADN-PS_543374_0911_SP13.book Seite 3 Mittwoch, 31. August 2011 12:23 12 Delivery includes Components required for operation Central unit/ Power supplies Number Description Cat. No. Function 1 ADN CU1-EU central unit, EU version 505553 Controls the conference and supplies power to max.
KA_ADN-PS_543374_0911_SP13.book Seite 4 Mittwoch, 31. August 2011 12:23 12 Product overview ADN PS power supply Product overview ADN PS power supply 1 2 3 4 5 1 ADN PS PORT II PORT I DATA CU/PS 1 2 1 PS 2 100 - 240V 50/60Hz 385W PORT I & PORT II: max. 5.
KA_ADN-PS_543374_0911_SP13.book Seite 5 Mittwoch, 31. August 2011 12:23 12 Structuring and controlling the conference system Structuring and controlling the conference system Structuring the conference system The ADN conference system is suitable for conferences with up to 400 conference units.
KA_ADN-PS_543374_0911_SP13.book Seite 6 Mittwoch, 31. August 2011 12:23 12 Structuring and controlling the conference system Large conference system with simple cabling For setting up a large conference system with the maximum number of conference units (i.e. up to 400), you require one ADN CU1 central unit for controlling the conference and additional ADN PS power supplies for powering the conference units.
KA_ADN-PS_543374_0911_SP13.book Seite 7 Mittwoch, 31. August 2011 12:23 12 Structuring and controlling the conference system Large conference system with redundant ring topology The redundant ring topology ensures that, should one conference unit or system cable fail or be manipulated, all other conference units of the cable ring will continue to function reliably.
KA_ADN-PS_543374_0911_SP13.book Seite 8 Mittwoch, 31. August 2011 12:23 12 Preparing the ADN PS power supply for use Preparing the ADN PS power supply for use Setting up the power supply CAUTION Danger of material damage and personal injury due to stacked power supplies! When stacking several ADN PS power supplies on top of each other, • the stack may topple over, • the temperature of the individual ADN PS power supplies may drastically increase, • high mechanical loading may be exerted on e.g.
KA_ADN-PS_543374_0911_SP13.book Seite 9 Mittwoch, 31. August 2011 12:23 12 Setting up the conference system Setting up the conference system CAUTION Product damage due to an unsuitable power supply! If you connect standard network devices with RJ45 plugs (e.g. switches or network cards) to the connection sockets PORT I and PORT II, the network devices can be damaged due to an unsuitable power supply. 왘 Only connect ADN C1 and ADN D1 conference units to the connection sockets PORT I and PORT II.
KA_ADN-PS_543374_0911_SP13.book Seite 10 Mittwoch, 31. August 2011 12:23 12 Setting up the conference system Connecting ADN PS power supplies to the ADN CU1 central unit For conference systems comprising more than 40 conference units or when the conference units are connected in a redundant ring topology, you require ADN PS power supplies. A max. of 15 ADN PS power supplies can be used in a conference system.
KA_ADN-PS_543374_0911_SP13.book Seite 11 Mittwoch, 31. August 2011 12:23 12 Setting up the conference system ADN PS PORT II PORT I DATA CU/PS 1 2 1 ADN D1/ADN C1 PS 2 100 - 240V 50/60Hz 385W PORT I & PORT II: max. 5.25A sum 쐅 6789 PORT I 1 2 PORT II 1 2 IN OUT 쐈 IN OUT IN OUT ADN PS ADN CU1 ADN PS PORT I IN OUT ...20 1 IN OUT 1 OUT PORT I 2 IN OUT IN 1 ...20 PORT II IN OUT 1 IN OUT 1 ...20 PORT II 2 OUT IN OUT IN 1 ... 20 PORT I OUT IN ...
KA_ADN-PS_543374_0911_SP13.book Seite 12 Mittwoch, 31. August 2011 12:23 12 Setting up the conference system Setting up large conference system comprising ADN PS power supplies conference units connected in redundant ring topology In large conference systems with up to 400 conference units, the redundant ring topology ensures that, should one conference unit or system cable fail or be manipulated, all other conference units of the cable ring will continue to function reliably.
KA_ADN-PS_543374_0911_SP13.book Seite 13 Mittwoch, 31. August 2011 12:23 12 Setting up the conference system ADN PS PORT I PORT II DATA CU/PS 1 2 1 ADN D1/ADN C1 PS 2 100 - 240V 50/60Hz 385W PORT I & PORT II: max. 5.25A sum 쐅 6789 PORT I 1 2 PORT II 1 2 IN OUT IN OUT PORT I PORT II PORT I PORT II 1 1 1 1 2 IN 1 2 IN OUT OUT IN OUT ADN PS ADN PS ADN CU1 쐈 ... 20 IN 1 OUT 2 IN 1 OUT ... 20 IN IN OUT OUT 2 ... 20 IN 1 OUT OUT ...
KA_ADN-PS_543374_0911_SP13.book Seite 14 Mittwoch, 31. August 2011 12:23 12 Switching the ADN PS power supply on/off Switching the ADN PS power supply on/off The ADN PS power supplies can only be switched on when the central unit and the previous ADN PS connected in series are also switched on. You can set up your conference system so that you can increase or reduce the number of conference units used by simply switching individual ADN PS on or off.
KA_ADN-PS_543374_0911_SP13.book Seite 15 Mittwoch, 31. August 2011 12:23 12 Cleaning and maintaining the conference system Cleaning and maintaining the conference system CAUTION Liquids can damage the product! Liquids entering the product can cause a short-circuit in the electronics or damage the mechanics. Solvents or cleansing agents can damage the surfaces of the product. 왘 Keep all liquids away from the product. 왘 Do not use any solvents or cleansing agents.
KA_ADN-PS_543374_0911_SP13.book Seite 16 Mittwoch, 31. August 2011 12:23 12 Specifications ADN PS Specifications ADN PS 16 | ADN PS Dimensions 482.5 x 168 x 100 mm (B x H x D) Weight approx. 4.6 kg Nominal input voltage 100 to 240 V~ Mains frequency 50 to 60 Hz Power consumption 385 W Output voltage at RJ45 PORT I/II output 1/2 52.8 V Nominal output current at RJ45 PORT I/II output 1/2 max. 5.25 A in total max. 1.75 A per output Output voltage at RJ45 DATA 52.