Audiobeam Instructions for use
Contents Safety instructions ......................................................................................................................... 2 Warning – High Voltage – Risk of Death! ................................................................................... 2 Risk of fire! ........................................................................................................................................ 2 Attention! .....................................................................
Safety instructions Warning – High Voltage – Risk of Death! Opening the Audiobeam while it is connected to the mains is likely to result in a lifethreatening electric shock! There are no user serviceable parts inside – if the Audiobeam should become defective, any repairs must be carried out by an official Sennheiser Service Partner. If the unit is opened in breach of this instruction, the warranty becomes null and void.
Connections and operating controls Delivery includes y Audiobeam y 3 mains cables with connectors y 5/8" thread with adapter to 3/8" thread y Instruction for use y Warranty Certificate LED operation indicator: green: Audiobeam is operational (standby) red: Audiobeam is not operational Sensitivity selector switch (+6 dBm, –14 dBm) On/off switch for distance sensor is set to “ON” (please observe “Distance sensor” on page 4 and following!) XLR-3 socket for audio input INPUT O
Mounting Audiobeam Correct mounting conditions 왘 When mounting Audiobeam, make sure that: y the ultrasonic sound wave can travel undisturbed for at least 1 m before it strikes the first surface. y a minimum distance of 10 cm is maintained between Audiobeam and adjacent objects so that any heat generated can dissipate. Make sure that the air vents at the top and rear of the unit are not covered or blocked! y a minimum distance of 1 meter is maintained between Audiobeam and combustible materials.
왘 Use an XLR-3 cable to connect the audio source (e.g. CD or DVD player, mixing console, receiver of a wireless microphone) to the audio input INPUT . Audiobeam automatically emits ultrasound as soon as an audio signal (see “Specifications”‘ on page 6) is present at the audio input INPUT . 왘 Use the mains cable to connect Audiobeam to the mains. Secure the mains cable with the steel clamp . 왘 The LED operation indicator lights up green, indicating that Audiobeam is ready for operation (standby).
Specifications Modulation: wideband AM Carrier frequency: 40 kHz Peak limiter: limiter amplifier Audio channels: 1 Audio input: XLR-3F socket, balanced, DC-isolated Input level for max. peak SPL: +6 dBm (1.55 V) = upper switch position –14 dBm (150 mV) = lower switch position Switching threshold: –46 dBm (4 mV) = upper switch position –66 dBm (0.
Manufacturer declarations Warranty regulations The guarantee period for this Sennheiser product is 24 months from the date of purchase. Excluded are accessory items and disposable batteries that are delivered with the product; due to their characteristics these products have a shorter service life that is principally dependent on the individual frequency of use. The guarantee period starts from the date of original purchase.
Sennheiser electronic GmbH & Co. KG 30900 Wedemark, Germany Phone +49 (5130) 600 0 Fax +49 (5130) 600 300 www.sennheiser.com Printed in Germany Publ.