Instruction manual Digital 9000 System

Table Of Contents
Digital 9000 | 77
Using the EM 9046
To synchronize the settings with your transmitters via infra-red:
Select
one of the channels 1–8.
Switch on the transmitter to which you want to assign this channel.
Press the button J on the EM 9046.
The receiver switches to synchronization mode and the LED B
flashes.
Place the transmitter’s infra-red interface in front of the infra-red
interface D of the receiver. Maintain a distance of approx. 10–20 cm
between the infra-red interfaces.
The transmitter and receiver are synchronized:
After pressing the button J, the receiver’s infra-red interface
searches for a suitable transmitter infra-red signal for 12 seconds.
You can interrupt the synchronization at any time by pressing the
button J again.
If a problem occurs during the synchronization process, read the
chapter “If a problem occurs ...” on page 110.
Repeat the above steps for the remaining transmitters.
Main menu “Channel setup
To get into the main menu:
Select the “ch” operating mode.
Select one or several channels (see page 52).
Call up the menu items described in the following and adjust your set-
tings.
Press the button to store your settings.
Synchronize your settings via infra-red (see page 77).
“Frequency” – Selecting a frequency preset or setting a frequency
manually
Via the “Frequency” menu item, you can select a frequency preset for the
active booster frequency range or set the frequency manually. In the
above diagram, range “A1” is active. The frequency range is from “470-
494 MHz”. For information on how to activate a booster frequency range,
refer to page 59.
Either select a frequency preset (“A1.1” ... “A1.40” in the above dia-
gram) or set the frequency manually (“U”). If you set the frequency
manually, make sure to set a frequency within the current 24 MHz
booster frequency range and maintain a frequency spacing of 600 kHz
to avoid intermodulation interference.
If no channel is selected, “Please select Channel” is displayed in the
menu selection.
Preset A1.1 Freq 470 . 200 MHz
Range: 470 - 494 MHz
frequency