e 965 Instruction manual
Delivery includes Delivery includes • e 965 • MZQ 800 microphone clamp • pouch • quick guide • safety guide Product overview 2 1 5 4 3 0 -10 dB 1. Sound inlet basket 2. XLR-3 connector 3. Directivity switch 4. Sensitivity switch 5.
Installation Installation Attaching the microphone f Screw the microphone clamp to a stand. f Place the microphone with its back end into the microphone clamp. f Orient the microphone together with the microphone clamp. Connecting the microphone f Connect the XLR-3 socket of the microphone cable (optional accessories) to the XLR-3 socket of the microphone. Using the windshield f Place the MZW 4032 (optional accessories) windshield over the microphone head.
Operation Operation Holding the microphone If you cover the microphone head during transmission, this will change the pick-up pattern of the microphone and consequently the sound. f Only hold the microphone by its body.
Operation Positioning the monitor loudspeakers f To prevent feedback and crosstalk, postion your monitor loudspeakers in the angle area of the highest cancellation of the microphone (cardioid: 180°; super-cardioid: 135°).
Operation Using the microphone CAUTION DANGER OF DAMAGE TO THE MICROPHONE! The switches on the microphone can be damaged if you try to operate them using tools. f Only operate the switches on the microphone using your fingers. f Unscrew the sound inlet basket. Adjusting the pick-up pattern f Set the directivity switch to the desired position: Pos. Pick-up pattern Cardioid A cardioid pick-up pattern also picks up sound from the sides. This pattern is good for picking up several vocalists at once, e.g.
Cleaning and maintaining the e 965 Cleaning and maintaining the e 965 CAUTION LIQUIDS CAN DAMAGE THE ELECTRONICS OF THE PRODUCT! Liquids entering the housing of the product can cause a short-circuit and damage the electronics. f Keep all liquids away from the product. f Do not use any solvents or cleansing agents. f Disconnect the products from the power supply system and remove rechargeable batteries and batteries before you begin cleaning. f Clean all products only with a soft, dry cloth.
Specifications Specifications Transducer principle externally polarized dual-diaphragm condenser microphone Membran diameter 25.4 mm/1" Frequency response 40 - 20,000 Hz Pick-up pattern cardioid/super-cardioid, switchable Sensitivity (free field, no load) with preattenuation 7 mV/Pa 2.3 mV/Pa Nominal impedance (at 1 kHz) 50 Ω Min. terminating impedance 1 kΩ Max. sound pressure level (at 1 kHz) with preattenuation 142 dB 152 dB Equivalent noise level 21 dB(A) Phantomspeisung 48 V / 3.
Specifications Frequency response dBV -40 -50 -60 -70 -80 10 ,0 00 20 ,0 00 H z 20 ,0 00 H z 2, 00 0 2, 00 0 10 ,0 00 1,0 00 1,0 00 5, 00 0 50 0 50 0 0°, 1 m PAD 5, 00 0 20 0 20 0 10 0 50 -90 dBV -40 -50 -60 -70 -80 10 0 50 -90 0°, 1 m PAD Connector assignment 1 3 2 + XLR 1 3 XLR + + 2 3 + 1 XLR 2 2 3 1 XLR + + BALANCED 6.
Overview of applications Overview of applications Primary application Secondary application e 602 II e 604 e 608 e 609 silver e 614 e 835 e 845 e 865 e 901 e 902 e 904 e 906 e 908 e 914 e 935 e 945 e 965 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • e 965 | 10/10