Using the receiver
22
Synchronizing a transmitter with the receiver
You can synchronize a suitable transmitter of the ew 500 G3 series with
the receiver. If the receiver is in ex works condition, the following parame-
ters are transferred to the transmitter during synchronization:
To transfer the parameters:
왘 Switch the transmitter and the receiver on.
왘 Press the button on the receiver.
“Sync” appears on the display panel of the receiver.
왘 Place the infra-red interface of the transmitter (see the instruction
manual of the transmitter) in front of the infra-red interface of the
receiver.
The parameters are transferred to the transmitter. When the transfer
is completed, “ ” appears on the receiver’s display panel. The receiver
then switches back to the current standard display.
Setting Transferred parameters
“Frequency Preset” Currently set frequency
“Name” Freely selectable name currently set on the receiver
“Pilot Tone” Current pilot tone setting of the receiver
(“Inactive”/“Active”)
Via the “Sync Settings” submenu, you can adjust the parameters to
be transferred to your transmitters (see page 41). It is vital to
observe the notes on frequency selection on page 45.
쐋
쐋