System -> Wordclock menu item
In this menu item, you can configure the settings for the word clock.
To open the Wordclock menu item:
Turn the jog dial in the System menu item until the Wordclock menu
item appears in the selection frame.
Press the jog dial to open the menu.
The display shows you the option that is currently selected.
Turn the jog dial to choose between the following options:
Internal 48 kHz: Choose this option if you want to use the internal
word clock with a clock rate of 48 kHz.
Internal 96 kHz: Choose this option if you want to use the internal
word clock with a clock rate of 96 kHz.
External BNC: Choose this option if you use an external word clock
that is connected via the Wordclock In BNC input. See „Connecting
the word clock“.
External Dante: Choose this option if you use an external word clock
that is connected via the Dante interface. This option is available only
with the EM 6000 DANTE.
Press the SAVE button to save the setting.
For more information about the word clock, see „Word clock scenar-
ios for digital audio (AES3 and Dante™)“.