Instruction manual - Digital 6000 (v4.0)

Table Of Contents
Using the L 6000
172
LM 6060, LM 6061 and LM 6062 status LEDs
The LM 6060, LM 6061 and LM 6062 modules each have two charging
slots. Next to each charging slot, there is a status LED that displays the fol-
lowing status information:
Flashing red >> the charging slot or rechargeable battery is too
hot or too cold and the charging process was stopped.
Lights up red >> the rechargeable battery is defective.
Flashing yellow >> the rechargeable battery is being regenerat-
ed.
Lights up yellow >> the rechargeable battery is being charged.
Charge level 0% to 80%
Flashing green >> the rechargeable battery is being charged.
Charge level 81% to 96%
Lights up green >> the rechargeable battery is fully charged.
Charge level 100%
LM 6060, LM 6061 and LM 6062 status LEDs in storage mode
If you are operating the L 6000 charger in storage mode via WSM, the
meaning of the status indicators changes. You can find more information
under „Preparing rechargeable batteries for storage (storage mode)“.