Sound Control Protocol Digital 6000 (EM 6000 | L 6000)

Table Of Contents
SSC Developer‘s guide for Digital 6000 | 18/57
SSC Method List (EM 6000)
8.10 /rx1/freq/u1/00 - /rx1/freq/u1/99
This methods sets or returns the User Bank/Channel of each receiver channel.
type: Read/Write
value: number
Example:
Tx: {"rx1":{"freq":{"u1":{"00":null}}}}
Rx: {"rx1":{"freq":{"u1":{"00":470200}}}}
8.11 /rx1/freq/u2/00 - /rx1/freq/u2/99
see "”8.10 /rx1/freq/u1/00 - /rx1/freq/u1/99”"
8.12 /rx1/freq/u3/00 - /rx1/freq/u3/99
see "”8.10 /rx1/freq/u1/00 - /rx1/freq/u1/99”"
8.13 /rx1/freq/u4/00 - /rx1/freq/u4/99
see "”8.10 /rx1/freq/u1/00 - /rx1/freq/u1/99”"
8.14 /rx1/freq/u5/00 - /rx1/freq/u5/99
see "”8.10 /rx1/freq/u1/00 - /rx1/freq/u1/99”"
8.15 /rx1/freq/u6/00 - /rx1/freq/u6/99
see "”8.10 /rx1/freq/u1/00 - /rx1/freq/u1/99”"
8.16 /rx1/active_bank_channel
This method sets or returns active bank/channel for receiver channel 1.
type: Read/Write
value: [String Number]
bank limits: "b1/B1","b2/B2","b3/B3","b4/B4","b5/B5","b6/B6","u1/U1","u2/U2","u3/U3","--"
number limits: 0..99
Notes: if bank is set to "--" (Manual) then channel is don’t care.
Example:
Tx: {"rx1":{"active_bank_channel":["u2",63]}}
Rx: {"rx1":{"active_bank_channel":["u2",63]}}
Tx: {"rx1":{"active_bank_channel":null}}
Rx: {"rx1":{"active_bank_channel":["--",0]}} Manual mode active
8.17 /rx1/carrier
This method sets or returns the carrier Frequency in kHz for receiver channel 1.
type: Read/Write
value: Number
limits
type: Number
units: kHz
max: 713900
min: 470100
inc: 25
Example:
Tx: {"rx1":{"carrier":null}}
Rx: {"rx1":{" carrier ":470100}}