Sound Control Protocol Digital 6000 (EM 6000 | L 6000)

Table Of Contents
SSC Developer‘s guide for Digital 6000 | 47/57
SSC Method List (L 6000)
11.22 /slot3/subslot1/accu_detection
See "”11.4 /slot1/subslot1/accu_detection”".
type: Read
value: Bool
subscribable
limits
type: Boolean
11.23 /slot3/subslot2/led
See "”11.1 /slot1/subslot1/led”".
type: Read
value: String
subscribable
limits
type: String
options , option_desc
1. OFF , No battery detected
2. GREEN , State of charge in range 97% - 100%
3. GREEN_FLASHING , State of charge in range 81% - 96%
4. YELLOW , State of charge in range 0% - 80%
5. YELLOW_FLASHING , Battery in regeneration
6. RED , Battery defect
7. RED_FLASHING , Temperature out of range (normal operating temp: 0°C - 50°C)
8. GREEN_RED_FLASHING , Storage Mode: no battery detected
9. YELLOW_RED_FLASHING , Storage Mode: when battery is out of storage capacity
(69% - 71%)
10. YELLOW_GREEN_FLASHING , Storage Mode: battery has storage capacity
(69% - 71%)
11. DEV_IDENTIFY , Identify battery
11.24 /slot3/subslot2/identify
See "”11.2 /slot1/subslot1/identify”".
type: Read-only
11.25 /slot3/subslot2/accu_parameter
See "”11.3 /slot1/subslot1/accu_parameter”".
type: Array
value: Number
subscribable
11.26 /slot3/subslot2/accu_detection
See "”11.4 /slot1/subslot1/accu_detection”".
type: Read
value: Bool
subscribable
limits
type: Boolean