Users Manual
Table Of Contents
- Digital_9000_Manual_06_2017_EN
- Important safety instructions
- Digital 9000 – System overview
- Delivery includes
- EM 9046 receiver
- EM 9046 CAB cable set
- Antennas and antenna boosters
- GZL 9000 antenna cables
- SKM 9000/SKM 9000 COM radio microphone
- Microphone heads for the SKM 9000 radio microphone
- SK 9000 bodypack transmitter
- Microphones for the SK 9000 bodypack transmitter
- KA 9000 COM command adapter for the SK 9000 bodypack transmitter
- CI 1-4 line/instrument cable for the SK 9000 bodypack transmitter
- B 60/B 61 battery packs
- BA 60/BA 61 accupack
- L 60 charger
- Product overview
- EM 9046 receiver
- Antennas and antenna boosters
- GZL 9000 antenna cable
- SKM 9000/SKM 9000 COM radio microphone
- SK 9000 bodypack transmitter
- KA 9000 COM command adapter for the SK 9000 bodypack transmitter
- BA 60 accupack
- BA 61 accupack
- B 60 battery pack
- B 61 battery pack
- L 60 charger
- Preparing the EM 9046 receiver for use
- Preparing the A/AB/AD 9000 antennas and/or antenna boosters for use
- Preparing the SKM 9000 radio microphone for use
- Preparing the SK 9000 bodypack transmitter for use
- Preparing the L 60 charger for use
- Cascading several chargers
- Setting up or mounting the charger
- Preparing the Digital 9000 system for use
- Using the EM 9046
- Using the SKM 9000
- Using the SK 9000
- Using the L 60
- Cleaning and maintaining the Digital 9000 system
- If a problem occurs ...
- Specifications
Preparing the Digital 9000 system for use
36 | Digital 9000
Connecting external word clock signals
The EM 9046 receiver supports external word clock sampling rates of
44.1 kHz, 48 kHz, 88.2 kHz and 96 kHz. If you have installed a MAN card,
you can alternatively use the card‘s word clock as external word clock gen-
erator.
왘 (This step is not required if you use the word clock signal of a built-in
MAN card.)
Use a shielded 75 coaxial BNC cable to connect the word clock output
of an external word clock generator to the BNC socket 9 of the
EM 9046.
왘 Connect the BNC sockets of the receivers.
If you have daisy chained your receivers (see page 35):
왘 Connect the BNC sockets of the receivers in the order shown on page 35.
Connecting receivers in a network
The EM 9046 has two network sockets LAN UP 3 and LAN DOWN 4,
allowing you to connect additional EM 9046 or other network-compatible
Sennheiser receivers in a network.
All receivers in the network can be controlled via the Wireless Systems
Manager (WSM) software. In addition, interconnected receivers allow you
to simultaneously headphone monitor the channels of all receivers and the
stream arbitrary channels to an external audio player or to the WSM.
There are two ways to connect several EM 9046 in a network:
1. Ethernet daisy chaining:
EM9046
AB DCEF
BNC (Word Clock in)
9
For an overview of the states of the clock LED, refer to page 20.