Instruction manual 300 IEM Series G3 Download300 IEM Series: SR 300 IEM G3 and EK 300 IEM G3
Table Of Contents
- Important safety instructions
- The evolution wireless series ew 300 IEM G3
- The frequency bank system
- Product overviews
- Putting the devices into operation
- Putting the SR 300 IEM G3 transmitter into operation
- Setting up the transmitter on a flat surface
- Mounting the transmitter into a 19” rack
- Connecting the mains unit
- Connecting devices to the input sockets
- Connecting devices to the output sockets
- Connecting a remote antenna to the BNC socket and positioning the antenna
- Connecting the AC 3 antenna combiner to the BNC socket
- Daisy chaining audio signals
- Connecting transmitters in a network
- Putting the EK 300 IEM G3 diversity receiver into operation
- Putting the SR 300 IEM G3 transmitter into operation
- Using the devices
- Switching the devices on/off
- Monitoring the audio signal via headphones
- Deactivating the lock mode temporarily
- Selecting a standard display on the diversity receiver
- Adjusting the audio channels on the transmitter
- Activating/deactivating the RF signal on the transmitter
- Synchronizing transmitters and EK 300 IEM G3 receivers via the infra-red interface
- Using the operating menus
- Synchronizing the transmitter with the diversity receiver
- Cleaning the devices
- If a problem occurs ...
- Specifications
- Manufacturer Declarations
The frequency bank system
4
The frequency bank system
Transmitter and receiver are available in 7 UHF frequency ranges with 1,680 frequencies per
frequency range:
Each frequency range (A–E, G, GB) offers 26 frequency banks with up to 16 channels each:
Each of the channels in the frequency banks “1” to “20” has been factory-preset to a fixed
frequency (frequency preset). The factory-preset frequencies within one frequency bank are
intermodulation-free. These frequencies cannot be changed.
For an overview of the frequency presets, please refer to the supplied frequency information
sheet. Updated versions of the frequency information sheet can be downloaded from the
corresponding product page on our website at www.sennheiser.com.
The frequency banks “U1” to “U6” allow you to freely select and store frequencies. It might
be that these frequencies are not intermodulation-free (see page 28).
Range
GB:
606 – 648
516 – 558 566 – 608 626 – 668 734 – 776 780 – 822 823 – 865
Range A:
Range G:
Range B: Range C:
Range D:
Range E:
Frequency bank 1... 20
Frequency bank U1 ... U6
Channel 32 – frequency preset
Channel 1 – frequency preset
Channel 2 – frequency preset
Channel 32 – freely selectable frequency
Channel 1 – freely selectable frequency
Channel 2 – freely selectable frequency