Specifications
Table Of Contents
- Safety instructions
- Intended use of the system
- Operating the EZL 2020-20 L charging case
- Servicing
- Symbols on adhesive labels attached to the EZL 2020-20 L charging case
- Attention! High Volume!
- Safety instructions for Li-poly and NiMH rechargeable batteries and batteries
- Additional safety instructions for the BA 2015 accupack and for batteries
- System components
- Overview of the system
- The operating controls
- SK 2020 D bodypack transmitter
- HDE 2020 D stethoset receiver
- EZL 2020-20 L charging case
- Indications and displays on the transmitter
- Indications and displays on the receiver
- Indications and displays on the charging case
- The functions of the transmitter operating controls
- The functions of the receiver operating controls
- The functions of the operating controls of the charging case
- Putting the components into operation
- Using the components
- The operating menu of the transmitter
- Care and maintenance
- If problems occur...
- Specifications
- Accessoires
- Manufacturer declarations

28
Charging the rechargeable batteries
Charging the BA 2015 accupack
For charging, the BA 2015 accupack can remain in the
transmitter.
Place the transmitter with the accupack inserted
into the charging compartment for accupack/
transmitter as shown in the diagram on the left.
(Alternatively, you can remove the accupack from
the transmitter and insert it into the charging
compartment on its own – both charging compart-
ments are identical and can charge the occupied
either in or out of the transmitter.)
When placed into a charging compartment, the
transmitter automatically switches off. The red LED
CHARGE of the charging compartment lights up.
Charging a completely discharged accupack takes
approx. 3½ hours at room temperature. It is normal
for the accupacks to get hot during charging.
However, the charging process may take longer if:
y the accupack is deep-discharged and first has to be
reconditioned by a deep discharge recovery charge,
y the ambient temperature is close to or over 40 °C,
since, in order to protect the accupack, the charging
process will be interrupted until the temperature
has dropped to a safe level.
After the accupack has been fully charged, the green
LED READY lights up.
Notes:
y For safety reasons, each charging process will be
interrupted after 4 hours.
y When not using the BA 2015 accupack for
extended periods of time, charge it about every
three to six months.
y Only use the charging case for
charging the SK 2020 D transmitter,
the HDE 2020 D stethoset receivers
and the BA 2015 accupack.
y
Never try to charge other rechargeable
batteries or non-rechargeable batteries.
Caution!
쐋