Specifications
Table Of Contents
- Safety instructions
- Intended use of the system
- Operating the EZL 2020-20 L charging case
- Servicing
- Symbols on adhesive labels attached to the EZL 2020-20 L charging case
- Attention! High Volume!
- Safety instructions for Li-poly and NiMH rechargeable batteries and batteries
- Additional safety instructions for the BA 2015 accupack and for batteries
- System components
- Overview of the system
- The operating controls
- SK 2020 D bodypack transmitter
- HDE 2020 D stethoset receiver
- EZL 2020-20 L charging case
- Indications and displays on the transmitter
- Indications and displays on the receiver
- Indications and displays on the charging case
- The functions of the transmitter operating controls
- The functions of the receiver operating controls
- The functions of the operating controls of the charging case
- Putting the components into operation
- Using the components
- The operating menu of the transmitter
- Care and maintenance
- If problems occur...
- Specifications
- Accessoires
- Manufacturer declarations

29
Charging the receivers’ built-in rechargeable batteries
Place the receiver into one of the charging
compartments for receivers (slaves) .
The LED lights up (see table).
Charging a completely discharged rechargeable
battery takes approx. 2½ hours at room temperature.
However, the charging process may take longer if:
y the rechargeable battery is deep discharged and
first has to be reconditioned by a deep discharge
recovery charge,
y
the temperature of the built-in rechargeable battery
is over 43 °C or below 3 °C, since, in order to protect
the rechargeable battery, the charging process will
be interrupted until the temperature is again within
the admissible
range (the LED
flashes red).
After the built-in rechargeable battery has been fully
charged, the LED lights up green.
Notes:
y An additional temperature protection prevents
overheating inside the charging case. If the
temperature inside the charging case exceeds
safety limits, the charging process will be
interrupted and will only be restarted when the
charging case has cooled down.
y When not using the receivers for extended periods
of time, charge them about every six months in
order to prevent deep discharge damage to the
rechargeable batteries.
Color of LED Meaning
red
The built-in rechargeable battery is being
charged.
green
The built-in rechargeable battery is fully
charged.
red (flashing)
The temperature of the built-in
rechargeable battery is over 43 °C
or below 3 °C.
yellow/
orange
The built-in rechargeable battery is
defective. Interrupt the charging process
and contact your Sennheiser agent.