- How to read this manual
- Using the TeamConnect system
- The TeamConnect components
- TeamConnect Central Unit
- TeamConnect Combox
- Microphone Hub
- SpeechLine microphones and microphone accessories
- SpeechLine active loudspeakers
- Configuration Manager software
- SL TeamConnect CU1 - Product overview
- SL TeamConnect CB1 - Product overview
- SL Mic Hub 1 - Product overview
- Installing the SL TeamConnect CU1
- Establishing a network connection
- Connecting the SL TeamConnect CU1 to the telephone landline network
- Connecting the SL TeamConnect CB1 to the SL TeamConnect CU1
- Installing the SL TeamConnect CB1 in a meeting room
- Using the GPIO port of the SL TeamConnect CB1
- Connecting a computer
- Connecting a headset or an enterprise telephone
- Connecting the SL TeamConnect CU1 to a media control system
- Connecting and positioning microphones
- Connecting microphones using the SL Mic Hub 1
- Connecting microphones directly to the SL TeamConnect CU1
- Connecting auxiliary audio devices
- Connecting audio output signals
- Preparing the Quick Guide and the Room Sticker for the user
- The Configuration Manager software
- Installing the Configuration Manager software
- Connecting a computer for configuring the system
- Navigating the Configuration Manager software
- Configuring the SL TeamConnect CU1
- Configuring microphone settings
- Configuring audio processing settings
- Configuring line input settings
- Configuring audio output settings
- Configuring teleconference settings
- Configuring the settings of the SL TeamConnect CB1
- Configuring communication settings
- Using the Device Toolbox
- Using the Mixer Console
- Using presets
- Specifications
- Manufacturer Declarations
TeamConnect | 55
The Configuration Manager software
Configuring communication settings
The settings of the network and serial connections of the SL TeamConnect CU1
are configured in the Communications area of the configuration screen.
To configure the communication settings:
X Click on the Communications icon in the configuration screen.
The Communication Settings configuration window opens.
The Communication Settings configuration window has two tabs where you
can adjust the following settings:
Tab Option Settings
Networking MAC address Indicates the MAC address of the
SL TeamConnect CU1.
Device Name Defines the name of the
SL TeamConnect CU1 device in
the network. The device name is
required for the address of the
browser-based dialer. The address is
http://DeviceName.
Example:
• Device name: TeamConnect-123
• Address of browser-based dialer:
http://TeamConnect-123
Room Name Defines the room name required to
access the SL TeamConnect CU1 in the
mobile dialer iOS App.
Use DHCP Defines if the IP address is obtained
automatically (DHCP is activated)
or if the IP address is static (DHCP is
deactivated).
Use DNS Defines if a domain name system is
used for static IP addresses.
IP Filters Defines up to 4 IP filters. If an IP
filter is defined, only the devices
with the IP addresses entered in the
IP Filters area can connect to the
SL TeamConnect CU1 via an Ethernet
connection.
Change Admin
Login
Defines the username and
password required to access the
SL TeamConnect CU1 via an Ethernet
connection in the Configuration
Manager software.
Change Room
Password
Defines the room password required to
access the meeting room in the mobile
dialer iOS App and the browser-based
dialer.
Serial Baud Rate Adjusts the data rate of the RS-232
control port.
Flow Control Manages the data rate between two
data nodes, preventing a fast sender
from outrunning a slow receiver.
X Open the respective tab to adjust the desired settings.