Datasheet
Cat. No. 003109
MKH 50 P 48
Microphones | MKH Condenser Microphones
General Description
The super-cardioid MKH 50 offers a higher attenuation of diffuse-field
and lateral sound than the cardioid microphone. It is principally designed
for use as a soloist’s or spot microphone for applications requiring a high
degree of side-borne sound muting and feedback rejection. The direc-
tional characteristics are frequency-independent.
Features
䊏
High rejection of lateral sounds
䊏
Exceptionally low inherent self-noise
䊏
Transformerless and fully floating balanced output
䊏
Symmetrical transducer technology ensures extremely low distortion
䊏
Switchable roll-off filter to compensate for proximity effects
at a distance of appx. 0.5 m (1.64 ft)
䊏
Switchable pre-attenuation
䊏
Black, anodised light metal body
䊏
Delivery includes: 1 MKH 50, 1 MZS 40 shock mount,
1 MZW 41 windshield
Recommended Accessories
䊏
MZA 14 P 48 U battery power supply unit Cat. No. 002960
䊏
MZT 441 table stand Cat. No. 000799
䊏
MZT 100table stand Cat. No. 001883
䊏
MZD 30 dual clip, for MS stereo Cat. No. 002990
䊏
MZB 415 fish pole Cat. No. 000972
䊏
MZS 40 shock mount Cat. No. 003017
䊏
MZW 41 foam windshiel Cat. No. 029681
䊏
MZP 40 popshield Cat. No. 003132
䊏
MZS 20-1 shock mount Cat. No. 003609
䊏
MZW 20-1 basket windshield Cat. No. 003606
䊏
MZH 20-1 hairy cover Cat. No. 003610
Technical Data
Pick-up pattern ...........................................................super-cardioid
Frequency response .................................................40 – 20,000 Hz
Sensitivity (free field, no load, 1 kHz) ........25 (8) mV/Pa ± 1 dB
Nominal impedance ................................................................. 150 ⍀
Min. terminating impedance .....................................................1 k⍀
Equivalent noise level
A-weighted (DIN IEC 651) ............................................... 12 (18) dB
CCIR-weighted (CCIR 468-3) ........................................... 21 (27) dB
Max. sound pressure level .........................134 (142) dB at 1 kHz
Power supply ........................................................phantom 48 ± 4 V
Supply current ............................................................................. 2 mA
Dimensions ................................Ø 25 x 153 mm (Ø 0.98˝ x 6.02˝)
Weight ............................................................ appx. 100 g (3.53 oz)
Values in parentheses with attenuator switched on (–10 dB)
Cable pictured is an accessory not supplied with the microphone
Profile
Super-cardioid studio directional microphone with switchable
pre-attenuation and switchable roll-off filter. Frequency
response 40 Hz – 20,000 Hz, sensitivity (free field, no load)
25 (8) mV/Pa ± 1dB at 1 kHz, nominal impedance 150 ⍀,
min. terminating impedance 1 k⍀, equivalent noise level
A-weighted 12 (18) dB, CCIR-weighted 21 (27) dB, max. SPL
134 (142) dB at 1 kHz, phantom powering 48 ± 4 V, supply
current 2 mA, dimensions Ø 25 x 153 mm (Ø 0.98˝ x 6.02˝),
weight appx. 100 g (3.53 oz). Values in parentheses with atte-
nuator switched on (–10 dB).
Effect of switchable roll-off filter