Users Manual
Using the SK 6212
169
To enable the lock-off:
▷ Open the Lock menu item and set the value to On.
▷ Save your entry by pressing the SET button.
The automatic lock-off function will remain activated.
The display switches off.
To temporarily deactivate the lock function (TEMP UNLOCK):
▷ Press the ON/OFF/ESC button.
The display is reactivated.
▷ Press the ON/OFF/ESC button again.
The message LOCKED is shown on the display.
▷ Press the UP or DOWN button.
The message UNLOCK is shown on the display.
▷ Press the SET button.
The lock-off function is now temporarily disabled.
You can change settings as needed in the menu. The lock-off function
is reactivated after 10 seconds of inactivity.
To completely deactivate the lock-off function:
▷ Open the Lock menu item and set the value to Off.
▷ Save your entry by pressing the SET button.
The automatic lock-off function will remain disabled.
Test Tone menu item
In this menu item, you can activate a 1 kHz test tone that the transmitter
transmits instead of the input signal. Use this function to level out the sys-
tem and during the walk test.
Power LED menu item
In this menu item, you can set the behavior of the LED above the SK 6212’s
display and the ON/OFF button.
On: The LED remains continuously lit.
Lock off: The LED switches off once the lock-off function is enabled.
RF Power menu item
You can configure the transmission power in two steps in this menu item:
• Standard: 15 mW transmission power
• Low: 3.5 mW transmission power