Instruction manual SpeechLine Digital Wireless

Table Of Contents
The CHG 4N charger
191
signed IP. Once a DHCP server is available, however, the IP
addresses assigned by the server will be used.
Integrating the CHG 4N charger into a network with-
out DHCP using Fixed IP
If there is no DHCP server in the network and you are working
with fixed IP addresses, please observe the following informa-
tion.
The CHG 4N charger is delivered with automatic IP assign-
ment configured by default. After adding it in the Sennheiser
Control Cockpit, you can reconfigure it to Fixed IP. To do so,
proceed as described above: „Integrating the CHG 4N charger
into a network without DHCP using Auto IP“.
If you wish to do this, you must temporarily reconfigure the
host PC on which the Sennheiser Control Cockpit is installed
to automatic IP assignment.
If the CHG 4N charger is visible in the Sennheiser Control
Cockpit, you can do the IP configuration manually:
Change the IP settings under Device Details -> Network in
the Sennheiser Control Cockpit.
Connecting a pre-configured CHG 4N charger to the
Sennheiser Control Cockpit
If mDNS is activated (factory setting), the CHG 4N charger is
automatically detected in the network.
If the charger has been reconfigured according to one of the
procedures described above and mDNS has been deactivated,
you can add the charger manually using the Add Device func-
tion in the Sennheiser Control Cockpit.
To add the charger in the Sennheiser Control Cockpit:
Use the Add Device function in the Sennheiser Control
Cockpit and enter the pre-configured IP address.
Resetting the CHG 4N charger’s network settings
To reset the network settings to their factory defaults:
Use a pointed object to press the small reset button for at
least one second.
The settings will be reset once you release the reset button.
The factory settings are restored:
Automatic IP assignment
mDNS is activated