Instruction manual - XS Wireless 1 & XS Wireless 2

EM-XSW 2 rack receiver
60
Installing receivers in a rack
CAUTION
Rack mounting poses risks
When installing the device in a closed 19" rack or multi-rack
assembly, please consider that, during operation, the ambient
temperature, the mechanical load and the electrical potentials
will be different from those of devices which are not mounted
into a rack.
Make sure that the ambient temperature within the rack
does not exceed the permissible temperature limit stated
in the specifications. See „SPECIFICATIONS“.
Ensure sufficient ventilation; if necessary, provide addi-
tional ventilation.
Make sure that the mechanical load of the rack is even.
When connecting to the power supply system, observe the
information indicated on the type plate. Avoid overloading
the circuits. If necessary, provide overcurrent protection.
When mounting in a rack, please note that intrinsically
harmless leakage currents of the individual power supply
units may accumulate, thereby exceeding the permissible
limit value. As a remedy, ground the rack via an additional
ground connection.
To mount the receiver in a rack, you will need the GA 1-XSW 2
rack mount kit (see „Accessories“).