Instructions / Assembly

Sensaphone 1400 Manual
112
SOUND LEVEL MONITORING:
Problem 1
False high sound alarms occur frequently.
Problem 2
High sound does not cause an alarm.
Cause
a)Themicrophoneisnotclose
enough to the high sound source,
or the programmed sound setting
results in a lack of sensitivity to
high sound.
b)Noremotemicrophone(optional)
connected to the unit.
Solution
Move the microphone closer or
reprogram the sound sensitivity.
Refer to Chapter 4.
Connect a remote microphone to the
Mic terminals.
Cause
a)Theprogrammedsoundsensitivity
results in over-sensitivity to non-
alarm sound as well as alarm
sound.
b)SoundRecognitionTimeistoo
short.
Solution
Reprogram the sound sensitivity
(calibration).RefertoChapter4.
Lengthen the sound Recognition
Time. Refer to Chapter 4.