Users manual Owner manual

Chapter 2: Installation
11
6.750
3.5
SENSAPHONE
®
REMOTE MONITORING SYSTEM
MENU UP
DOWN
ENTER
WSG30
WIRELESS SENSOR GATEWAY
Figure 2: Wall-mounted WSG30 Unit
TURNING OFF THE WSG30
Once the power supply is plugged-in the WSG30 will power up. If power is subsequently removed,
the internal battery will continue to power the device. If you wish to turn off the device completely,
you must enter the Power Down command at the keypad and then unplug the power supply. See steps
below:
1) Press Menu.
2) Arrow down to Diagnostics and press Enter.
3) Arrow down to Power Down and press Enter.
4) Unplug the Power Supply, then press OK (Enter).
BATTERY REPLACEMENT
The WSG30 uses one (1) 6V 1.3AH rechargeable battery (included) for backup power in the event that
main power fails. The unit will constantly recharge the battery.
In the event you need to replace the battery, be sure to use battery part # BAT-0020 (see Appendix C:
Accessories) to ensure compatibility. To remove or replace the battery, remove the (4) screws from the
bottom cover and separate the top and bottom parts of the enclosure. Remove the battery bracket and
disconnect the read & black terminals from the battery. Replace the battery, replace the bracket, and
attach the battery terminals.