Datasheet

PCV Series
• Proportional controller
• Ratings from 15A to 90A @ 240 VAC
• 2-7 V DC or 2-10 V DC analog input range
• For use with resistive loads only
PRODUCT SELECTION
A 09A 57A 05A 52A 51noitpircseD
2-7 VDC Control 7PCV2415 7PCV2425
2-10 VDC Control 10PCV2415 10PCV2425 10PCV2450 10PCV2475 10PCV2490
OUTPUT SPECIFICATIONS (1)
A 09A 57A 05A 52A 51noitpircseD
Operating Voltage (47-63Hz) [Vrms] 100-240 100-240 100-240 100-240 100-240
Transient Overvoltage [Vpk] 600 600 600 600 600
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 10 10
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) 200 200 200 200 200
Maximum Load Current (3) [Arms] 15 25 50 75 90
Minimum Load Current [Arms] 0.15 0.15 0.15 0.15 0.15
Maximum Surge Current (16.6ms) [Apk] 150 250 625 1000 1200
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6
Maximum I² t for Fusing (8.3 msec) [A² sec] 94 260 1620 4150 6000
Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5 0.5 0.5
INPUT SPECIFICATIONS (1)
xx42VCP01xx42VCP7noitpircseD
Control Voltage Range 2-7 VDC 2-10 VDC
Typical Input Current @ 5 VDC 4 mA 4 mA
GENERAL SPECIFICATIONS
sretemaraPnoitpircseD
Dielectric Strength, Signal to Load (50/60Hz) 2500 Vrms
Dielectric Strength, Signal to Base 2500 Vrms
Ambient Operating Temperature Range -30 to 80 °C
Ambient Storage Temperature Range -40 to 125 °C
Weight (typical) 3.5 oz. (100g)
Encapsulation Themaly Conductive Epoxy
Terminals Screws and Saddle clamps Furnished, Unmounted
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
Datasheet
Control Relays
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.

Summary of content (5 pages)