Datasheet
CX Series
• SIP SSR
• Ratings of 5A @ 660 VAC
• SCR output for heavy industrial loads
• AC or DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
•
CE Compliant to EN60950-1
PRODUCT SELECTION
Control Voltage 5 A 5 A 5 A
3-15 VDC CX240D5
4-15 VDC CX380D5 CX480D5
15-32 VDC CXE240D5 CXE380D5 CXE480D5
18-36 VAC CXE240A5
90-140 VAC CX240A5
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description CX240x5 CX380x5 CX480x5
Operating Voltage (47-63Hz) [Vrms] 12-280 48-530 48-660
Transient Overvoltage [Vpk] 600 1200 1200
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 0.1 0.1 0.1
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) 500 500 500
Maximum Load Current [Arms] 5 5 5
Minimum Load Current [Arms] 0.06 0.06 0.06
Maximum Surge Current (16.6ms) [Apk] 250 250 250
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.4 1.4 1.4
Maximum I²t for fusing (8.3 msec) [A² sec] 260 260 260
Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5
HP rating UL 508/IEC60947[HP/KW]: 240VAC 0.25/0.18 0.25/0.18 0.25/0.18
HP rating UL 508/IEC60947[HP/KW]: 380VAC NA 0.33/0.25 0.33/0.25
HP rating UL 508/IEC60947[HP/KW]: 480VAC NA NA 0.5/0.37