Datasheet

D06D Series
• Ratings from 60A to 100A @ 60 VDC
• Mosfet output
• UL Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
For Generation 3 datasheet click here
• DC control
• EMC Compliant to Level 3
• Epoxy Free Design
PRODUCT SELECTION
Control Voltage 60A 80A 100A
3.5-32 VDC D06D60 D06D80 D06D100
Not all part number combinations are available.
Contact Crydom Technical Support for information on
the availability of a specific part number.
*
Required for valid part number
For options only and not required for valid part number
AVAILABLE OPTIONS
Operating Voltage
06D: 1-60 VDC
Rated Load Current
60: 60 Amps
80: 80 Amps
100: 100 Amps
Series
06D 60
D
Termination
Blank: Screws & clamps
K: Installed standoffs with (1)
screws for PC Board mounting
Thermal Pad
Blank: Not Included
H: Included
K H
OUTPUT SPECIFICATIONS
(2)
Description 100A80A60A
Recommended Operating Voltage [Vdc] 1-48 1-48 1-48
Absolute Maximum Rating [Vdc]
60 60 60
Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.1 0.3
Maximum Load Current [Adc]
(1)(3) 60 80 100
Minimum Load Current [mA]
(4) 5 5 5
Maximum Surge Current (10 msec)[Adc] 180 220 270
Maximum On-State Voltage Drop @ Rated Current [Vdc] 0.6 0.7 0.5
Maximum On-State Resistance [RDS-ON][Ohms] 0.01 0.008 0.005
Thermal Resistance Junction to Case (Rjc) [°C/W] 0.73 0.73 0.51
Minimum Heat Sink for Rated Current @40°C [°C/W] 1 0.5 0.5
Maximum Pulse Width Modulation Frequency [Hz]
(5) 1000 900 700
INPUT SPECIFICATIONS
(2)
Description DC Control
Control Voltage Range 3.5-32 VDC
Maximum Reverse Voltage -32 VDC
Minimum Turn-On Voltage (6) 3.5 VDC
Must Turn-Off Voltage 1 VDC
Minimum Input Current (for on-state) 10 mA
Maximum Input Current 15 mA
Nominal Input Impedance Current Regulated
Maximum Turn-On Time [µsec] 100
Maximum Turn-Off Time [µsec] 150
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Datasheet