Datasheet
• Ratings from 25A to 90A @ 48-530 VAC
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
For Generation 3 datasheet click here
• AC or DC control
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
Series 1 480 VAC
PRODUCT SELECTION
90A75A50A25AControl Voltage
4-32 VDC D4825 D4850 D4875 D4890
90-280 VAC A4825 A4850 A4875 A4890
AVAILABLE OPTIONS
Control Voltage
A: 90-280 VAC
D: 4-32 VDC
Rated Load Current
25: 25 Amps
50: 50 Amps
75: 75 Amps
90: 90 Amps
Operating
Voltage
48: 48-530 VAC
Termination
Blank: Screw
F: Quick Connect (1)
(Up to 50 Amps)
K: Hex standoffs (2)
25
A
Thermal Pad
Blank: Not Included
H: Included
48
K HS
Snubber
Blank: Not Included
S: Included
Switching Type
Blank: Zero Voltage Turn-On
-10: Instantaneous Turn-On (3)
-10
OUTPUT SPECIFICATIONS
(4)
90A75A50A25ADescription
Operating Voltage (47-440Hz) [Vrms] (5) 48-530 48-530 48-530 48-530
Transient Overvoltage [Vpk] 800 800 800 800
Maximum Off-State Leakage Current @ Rated Voltage [mArms] (6) 1 1 1 1
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] 500 500 500 500
Maximum Load Current [Arms] (2)(7) 25 50 75 90
Minimum Load Current [mArms] 150 150 150 150
Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 239/250 597/625 954/1000 1145/1200
Maximum On-State Voltage Drop @ Rated Current [Vrms] 1.15 1.15 1.15 1.15
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]
0.8 0.45 0.3 0.27
285/259 1770/1621 4555/4150 6560/5976
Minimum Power Factor (at Maximum Load) 0.5 0.5 0.5 0.5
INPUT SPECIFICATIONS
(4)
Description D48xx A48xx
Control Voltage Range 4-32 VDC 90-280 Vrms (60Hz)
Maximum Reverse Voltage -32 VDC -
Minimum Turn-On Voltage 4.0 VDC (8) 90 Vrms
Must Turn-Off Voltage 1.0 VDC 10 Vrms
Minimum Input Current 7.0 mA 5.0 mA
Maximum Input Current 12 mA 10 mA
Nominal Input Impedance Current Regulated Current Regulated
Maximum Turn-On Time [msec] 1/2 Cycle (9) 20
Maximum Turn-Off Time [msec] 1/2 Cycle 30
Required for valid part number
For options only and not required for valid part number
Not all part number combinations are available.
Contact Crydom Technical support for information on
the availability of a specific part number.
*
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Datasheet
Panel Mount