Product Specifications

The Power To Get Work Done
dimensions.sensata.com800-553-6418
24 VDC PURE SINE INVERTER
2200W | 3300W |4800W | 5600W
FEATURES
SPECIFICATION TYPE 24/2200N 24/3300N 24/4800N 24/5600N
OUTPUT
Waveform Shape Pure Sine Wave, <5% THD Typical
Continuous Power Watts 2200 3300 4800 5600
Peak Power Watts 6600 9600 13200 16800
Voltage VAC 120 ± 5%
Continuous Current Amperes (AC) 18 28 40 47
Peak Current Amperes (AC) 55 80 110 140
Frequency Hz 60 Hz ± 0.05%
Motor Start Rating hp 1 2 2 3
INPUT
Nominal VDC VDC 24
Range VDC VDC 22 - 28
Current Ampers (DC) 110 165 240 280
PROPERTIES
Chassis Size L L L L
Warranty Years 4 Years, Advance Replacementrst 2 years
Temperature Degrees -2 to 60° (0° to 140° F)
UL Listed UL 458
Weight lbs. 42 69 90 140
DIMENSIONS L x W x H inches 16 x 17 10 18 x 20 x 12.5
CHARGER
Battery Charger 30 or 50 Amp 30 or 50 Amp 30 or 50 Amp 30 or 50 Amp
Output Current Amperes (DC) 50 75 100 160
Input Current Amperes (AC) 20 30 30 26
Input Voltage VAC 95-135 95-135 95-135 95-135
Bypass Relay Amperes (AC) Smart Relay Smart Relay Smart Relay Smart Relay
• Engineeredconstructionandcoolingmethods
• Thermallycontrolledcoolingfan
• EnclosedACandDCcableconnections
• RemoteON/OFFswitchhookup
• GFCIoutletprotection
• LEDindicationofExternalpower,Inverterpower,Lowinput
voltage,Hightemperature,&Overload
• Batteryvoltageindicatorwithpush-to-test
• Automaticelectronicshortcircuit/overloadprotection
• Automaticovertemperatureshutdown
• Outputcircuitbreakers
• Automaticlowbatteryshutdownat21VDC(within-rush
delay)
• OptionalCharger
Form 130899-24L (08-26-13)

Summary of content (1 pages)