The following is a diagram illustrating the network layout for a 150 meter x 150 meter warehouse:
1.1. Important Installation Notes
Regarding RF2 installation, the following important rules must be taken into consideration when
determining where to mount the Gateway and Repeater infrastructure components:
1. The Gateway and Repeater MUST be mounted inside a building, where they would not be
exposed to rain or dripping water. They are designed to be installed in an location with
temperatures in the range of 0C to 40C, 10% to 90% humidity, non-condensing.
2. The Gateway and Repeater MUST NOT be mounted in a location where they would be exposed
to an explosive atmosphere, a corrosive atmosphere or conductive debris.
3. The Gateway and Repeater MUST ONLY be installed with the antennas included in the kit.
Changing antenna types or installation of an outside antenna is not permitted and will void the
Agency Approvals for the system.
4. The Gateway and Repeater MUST ONLY be powered by a +12 Vdc SELV Limited Power Source
only.
5. The RF
2
system has been tested for compliance to relevant standards and approved. Changes or
modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED
BATTERIES ACCORDING TO THE INSTRUCTIONS.