SENSOR Hub Specifications (217E-C001)
Power Supply
Operating voltage
AC (100 ~ 260) V / 50/60 Hz
Mains supply current limit
0.18A @ AC 230 V, 0.3 A @ 115 V
Mains supply fuse
1A / AC 250 V
Mains supply fault threshold voltage
AC 60 V
Power supply
2 A @ DC 5 V
Quiescent current (I
min
)
80m A @ DC 5 V
Standby battery maximum capacity
(DC 3.7 V)
5.0 Ah
Maximum battery current draw@
maximum operating temperature
3 A
Wireless networking
Wireless radio interconnection
operating frequencies
916MHz
Number of connected devices
24
Maximum distance between connected
devices to gateway
a
200 m
Group mode configuration timeout
2 min
Miscellaneous
Operating temperature
(-5 ~ +40) °C
Operating humidity
(0 ~ 95) % RH, non-condensing
Storage temperature
(-25 ~ +80) °C
Storage humidity
(0 ~ 98) % RH, non-condensing
Dimensions (h × w × d)
(129 x 99 × 35) mm