Installation Guide

AMS-9080 CONTROLLER 8200-0914-01 REV. A
INSTALLATION GUIDE 17 of 22 *8200-0914-01*
Alert code
Alert code name
Action
61
Detector overrun
Recoverable
62
Alarm mailbox full
Recoverable
63
Host communication mailbox full
Recoverable. Reload the application software. If the error does not
eliminate, replace the pedestal.
64
Sequencer mailbox full
Recoverable
65
LDM power save active
Not an error. The LDM sent the system into power save mode.
66
LDM power save inactive
Not an error. The LDM sent the system to exit power save mode.
Local diagnostics
Use the CE ADS4 Platform Configurator to troubleshoot and change the AMS-9080 Controller’s parameters.
You require the following hardware:
A laptop computer.
A service cable, with a male RJ-10/22 phone connector on one end and a male RJ-11/12 connector
on the other.
A DB-9 to RJ-11/12 connector.
To connect the cables, complete the following steps:
1. Connect the DB-9 to RJ-11/12 connector to the DB-9 serial port on a laptop computer. Use only
Pin 2, Pin 3, and Pin 5.
2. Connect the RJ-11/12 connector on the service cable to the DB-9 connector.
3. Connect the RJ-10/22 connector on the service cable to the RS-232 port, J2 on the controller.
Remote diagnostics
If you install an AMS-9080 Controller and connect it to an Ethernet network, you can configure and service the
controller from a remote location.